Serum procalcitonin levels remain below the threshold of 0.5 ng/ml in all patients with uncomplicated cirrhosis, irrespective of the cause of the disease, while they are significantly elevated when bacterial infection complicates the course of the disease. A significant proportion of patients with acute alcoholic hepatitis on a cirrhotic background as well as of patients with acute on chronic viral hepatitis, without bacterial infection, exhibit serum procalcitonin levels above 0.5 ng/ml, suggesting that this cut-off value is probably not enough to discriminate between patients with or without bacterial infection within these subgroups of patients with liver disease.
Methotrexate (MTX) is a dihydrofolate reductase inhibitor that is used for the treatment of tumors and autoimmune diseases. Several automated binding assays are used in clinical practice and numerous chromatographic methods have been developed toward higher specificity and sensitivity. In the present study, phenyl cartridges were used for the solid-phase extraction (SPE) of MTX from human serum samples; subsequently, extracts were analyzed by reversed-phase high-performance liquid chromatography. Isocratic separation was implemented on a Kromasil-C18 column with a mobile phase consisting of 50 mM sodium acetate buffer (pH 3.6)-acetonitrile (89:11, v/v) and ultraviolet detection at 307 nm. MTX eluted in less than 12 min with no interference from impurities or 24 examined drugs. Detector response was linear in the range of 0.025-5.00 µΜ (coefficient of correlation > 0.99). Recovery from the serum was 93.1-98.2% and bias was < 8.3%. Intra-day and inter-day precision were <7.8 and 12.6%, respectively (n = 6). The limit of quantitation was 0.01 µM and the limit of detection was 0.003 µΜ. The method was validated by using serum samples from osteosarcoma patients treated with high-dose MTX (8-12 g/m(2)). In conclusion, the combined use of a phenyl-functionalized sorbent for SPE and a Kromasil-C18 column, and specific detection at 307 nm, assured a selective, fast, robust and cost-effective method for the monitoring of MTX in osteosarcoma patients under high-dose MTX treatment, thus contributing to more efficient treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.