Purpose:To investigate the feasibility of breast tissue characterization in terms of water, lipid, and protein contents with a spectral computed tomographic (CT) system based on a cadmium zinc telluride (CZT) photon-counting detector by using postmortem breasts.
Materials and Methods:Nineteen pairs of postmortem breasts were imaged with a CZT-based photon-counting spectral CT system with beam energy of 100 kVp. The mean glandular dose was estimated to be in the range of 1.8-2.2 mGy. The images were corrected for pulse pile-up and other artifacts by using spectral distortion corrections. Dual-energy decomposition was then applied to characterize each breast into water, lipid, and protein contents. The precision of the three-compartment characterization was evaluated by comparing the composition of right and left breasts, where the standard error of the estimations was determined. The results of dual-energy decomposition were compared by using averaged root mean square to chemical analysis, which was used as the reference standard.
Background-Electromagnetically Navigated Bronchoscopy (ENB) is currently the state-of-the art diagnostic and interventional bronchoscopy. CT-to-body divergence is a critical hurdle in ENB, causing navigation error and ultimately limiting the clinical efficacy of diagnosis and treatment. In this study, Visually Navigated Bronchoscopy (VNB) is proposed to address the aforementioned issue of CT-to-body divergence.Materials and Methods-We extended and validated an unsupervised learning method to generate a depth map directly from bronchoscopic images using a Three Cycle-Consistent Generative Adversarial Network (3cGAN) and registering the depth map to preprocedural CTs. We tested the working hypothesis that the proposed VNB can be integrated to the navigated bronchoscopic system based on 3D Slicer, and accurately register bronchoscopic images to pre-procedural CTs to navigate transbronchial biopsies. The quantitative metrics to asses the hypothesis we set was Absolute Tracking Error (ATE) of the tracking and the Target Registration Error (TRE) of the total navigation system. We validated our method on phantoms produced from the pre-procedural CTs of five patients who underwent ENB and on two ex-vivo pig lung specimens.Results-The ATE using 3cGAN was 6.2 +/− 2.9 [mm]. The ATE of 3cGAN was statistically significantly lower than that of cGAN, particularly in the trachea and lobar bronchus (p < 0.001). The TRE of the proposed method had a range of 11.7 to 40.5 [mm]. The TRE computed by 3cGAN was statistically significantly smaller than those computed by cGAN in two of the five cases enrolled (p < 0.05).Conclusion-VNB, using 3cGAN to generate the depth maps was technically and clinically feasible. While the accuracy of tracking by cGAN was acceptable, the TRE warrants further investigation and improvement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.