IntroductionProthrombin complex concentrates (PCC) are haemostatic blood preparations indicated for urgent anticoagulation reversal, though the optimal dose for effective reversal is still under debate. The latest generation of PCCs include four coagulation factors, the so-called 4-factor PCC. The aim of this study was to compare the efficacy and safety of two doses, 25 and 40 IU/kg, of 4-factor PCC in vitamin K antagonist (VKA) associated intracranial haemorrhage.MethodsWe performed a phase III, prospective, randomised, open-label study including patients with objectively diagnosed VKA-associated intracranial haemorrhage between November 2008 and April 2011 in 22 centres in France. Patients were randomised to receive 25 or 40 IU/kg of 4-factor PCC. The primary endpoint was the international normalised ratio (INR) 10 minutes after the end of 4-factor PCC infusion. Secondary endpoints were changes in coagulation factors, global clinical outcomes and incidence of adverse events (AEs).ResultsA total of 59 patients were randomised: 29 in the 25 IU/kg and 30 in the 40 IU/kg group. Baseline demographics and clinical characteristics were comparable between the groups. The mean INR was significantly reduced to 1.2 - and ≤1.5 in all patients of both groups - 10 minutes after 4-factor PCC infusion. The INR in the 40 IU/kg group was significantly lower than in the 25 IU/kg group 10 minutes (P = 0.001), 1 hour (P = 0.001) and 3 hours (P = 0.02) after infusion. The 40 IU/kg dose was also effective in replacing coagulation factors such as PT (P = 0.038), FII (P = 0.001), FX (P <0.001), protein C (P = 0.002) and protein S (0.043), 10 minutes after infusion. However, no differences were found in haematoma volume or global clinical outcomes between the groups. Incidence of death and thrombotic events was similar between the groups.ConclusionsRapid infusion of both doses of 4-factor PCC achieved an INR of 1.5 or less in all patients with a lower INR observed in the 40 IU/kg group. No safety concerns were raised by the 40 IU/kg dose. Further trials are needed to evaluate the impact of the high dose of 4-factor PCC on functional outcomes and mortality.Trial registrationEudra CT number 2007-000602-73.
The LG plasma product was bioequivalent to its predecessor with respect to recovery of clotting factors and demonstrated comparable safety and tolerability in healthy volunteers. Both products compensated well for the loss of clotting factors after apheresis (NCT01063595).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.