Preoperative anemia is independently associated with acute kidney injury after coronary artery bypass grafting. Further studies are warranted to determine whether preoperative low hemoglobin concentration is a marker of severity of illness or a modifiable risk factor.
Aim
Pre-transcatheter aortic valve implantation (TAVI) computed tomography (CT) has proven to be crucial in identifying pre- and post-procedural predicting factors predisposing the onset of major arrhythmias that require permanent pacemaker (PPM) implantation caused by the compressive effects of the prostheses on the conduction system at the membranous septum (MS) and the muscular crest of the interventricular septum.
Our analysis aims to verify if the pre-TAVI assessment of the angle between the MS and the aortic annulus (SVA) might be a predictive factor for the onset of arrhythmias that requires PPM.
Methods
Two cardiovascular specialist radiologists retrospectively and double-blind evaluated a randomized list of preprocedural CT of 57 patients who underwent TAVI with a self-expandable valve from April 2019 to February 2020. Two anatomical features were measured by readers: width of the SVA and MS length (MSL).
Results
A PPM was implanted in 18 patients (31%) after the procedure. There was no significant difference in the anatomical measurements performed between the two observers, regarding both anatomical measurements (intraclass correlation coefficient was 0.944 for the SVA and 0.774 for the MSL]. Receiver-operating characteristic curves (ROC) performed for both measurements have documented: for the SVA sensitivity 94% and Negative predictive value (NPV) 96% (area under the curve: 0.77; 95% confidence interval 0.66–0.90). The MSL ROC was not significant. The mean SVA value stratified for patients who did not undergo PPM implantation and patients who did resulted as significant (P < 0.005).
Conclusion
Measurement of the SVA performed in preprocedural CT scans has proven to be related to the onset of major arrhythmias after TAVI requiring permanent pacemaker implantation with high sensitivity (94%) and NPV (96%).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.