Background and purpose: In radiotherapy, automatic organ-at-risk segmentation algorithms allow faster delineation times, but clinically relevant contour evaluation remains challenging. Commonly used measures to assess automatic contours, such as volumetric Dice Similarity Coefficient (DSC) or Hausdorff distance, have shown to be good measures for geometric similarity, but do not always correlate with clinical applicability of the contours, or time needed to adjust them. This study aimed to evaluate the correlation of new and commonly used evaluation measures with time-saving during contouring. Materials and methods: Twenty lung cancer patients were used to compare user-adjustments after atlas-based and deep-learning contouring with manual contouring. The absolute time needed (s) of adjusting the auto-contour compared to manual contouring was recorded, from this relative time-saving (%) was calculated. New evaluation measures (surface DSC and added path length, APL) and conventional evaluation measures (volumetric DSC and Hausdorff distance) were correlated with time-recordings and time-savings, quantified with the Pearson correlation coefficient, R. Results: The highest correlation (R = 0.87) was found between APL and absolute adaption time. Lower correlations were found for APL with relative time-saving (R = −0.38), for surface DSC with absolute adaption time (R = −0.69) and relative time-saving (R = 0.57). Volumetric DSC and Hausdorff distance also showed lower correlation coefficients for absolute adaptation time (R = −0.32 and 0.64, respectively) and relative timesaving (R = 0.44 and −0.64, respectively). Conclusion: Surface DSC and APL are better indicators for contour adaptation time and time-saving when using auto-segmentation and provide more clinically relevant and better quantitative measures for automaticallygenerated contour quality, compared to commonly-used geometry-based measures.
Background and purpose: Quality of automatic contouring is generally assessed by comparison with manual delineations, but the effect of contour differences on the resulting dose distribution remains unknown. This study evaluated dosimetric differences between treatment plans optimized using various organ-at-risk (OAR) contouring methods. Materials and methods: OARs of twenty lung cancer patients were manually and automatically contoured, after which user-adjustments were made. For each contour set, an automated treatment plan was generated. The dosimetric effect of intra-observer contour variation and the influence of contour variations on treatment plan evaluation and generation were studied using dose-volume histogram (DVH)parameters for thoracic OARs. Results: Dosimetric effect of intra-observer contour variability was highest for Heart D max (3.4 ± 6.8 Gy) and lowest for Lungs-GTV D mean (0.3 ± 0.4 Gy). The effect of contour variation on treatment plan evaluation was highest for Heart D max (6.0 ± 13.4 Gy) and Esophagus D max (8.7 ± 17.2 Gy). Dose differences for the various treatment plans, evaluated on the reference (manual) contour, were on average below 1 Gy/1%. For Heart D mean , higher dose differences were found for overlap with PTV (median 0.2 Gy, 95% 1.7 Gy) vs. no PTV overlap (median 0 Gy, 95% 0.5 Gy). For D max -parameters, largest dose difference was found between 0-1 cm distance to PTV (median 1.5 Gy, 95% 4.7 Gy). Conclusion: Dose differences arising from automatic contour variations were of the same magnitude or lower than intra-observer contour variability. For Heart D mean , we recommend delineation errors to be corrected when the heart overlaps with the PTV. For D max -parameters, we recommend checking contours if the distance is close to PTV (<5 cm). For the lungs, only obvious large errors need to be adjusted.
published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.• Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal.If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the "Taverne" license above, please follow below link for the End User
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.