; for the Spanish Sleep Network IMPORTANCE More than 70% of patients with resistant hypertension have obstructive sleep apnea (OSA). However, there is little evidence about the effect of continuous positive airway pressure (CPAP) treatment on blood pressure in patients with resistant hypertension. OBJECTIVE To assess the effect of CPAP treatment on blood pressure values and nocturnal blood pressure patterns in patients with resistant hypertension and OSA. DESIGN, SETTING, AND PARTICIPANTS Open-label, randomized, multicenter clinical trial of parallel groups with blinded end point design conducted in 24 teaching hospitals in Spain involving 194 patients with resistant hypertension and an apnea-hypopnea index (AHI) of 15 or higher. Data were collected from June 2009 to October 2011. INTERVENTIONS CPAP or no therapy while maintaining usual blood pressure control medication. MAIN OUTCOMES AND MEASURES The primary end point was the change in 24-hour mean blood pressure after 12 weeks. Secondary end points included changes in other blood pressure values and changes in nocturnal blood pressure patterns. Both intention-to-treat (ITT) and per-protocol analyses were performed. RESULTS A total of 194 patients were randomly assigned to receive CPAP (n = 98) or no CPAP (control; n = 96). The mean AHI was 40.4 (SD, 18.9) and an average of 3.8 antihypertensive drugs were taken per patient. Baseline 24-hour mean blood pressure was 103.4 mm Hg; systolic blood pressure (SBP), 144.2 mm Hg; and diastolic blood pressure (DBP), 83 mm Hg. At baseline, 25.8% of patients displayed a dipper pattern (a decrease of at least 10% in the average nighttime blood pressure compared with the average daytime blood pressure). The percentage of patients using CPAP for 4 or more hours per day was 72.4%. When the changes in blood pressure over the study period were compared between groups by ITT, the CPAP group achieved a greater decrease in 24-hour mean blood pressure (3.1 mm Hg [95% CI, 0.6 to 5.6]; P = .02) and 24-hour DBP (3.2 mm Hg [95% CI, 1.0 to 5.4]; P = .005), but not in 24-hour SBP (3.1 mm Hg [95% CI, −0.6 to 6.7]; P = .10) compared with the control group. Moreover, the percentage of patients displaying a nocturnal blood pressure dipper pattern at the 12-week follow-up was greater in the CPAP group than in the control group (35.9% vs
Background: We used a validated inpatient satisfaction questionnaire to evaluate the health care received by patients admitted to several hospitals. This questionnaire was factored into distinct domains, creating a score for each to assist in the analysis.
NIV and CPAP were more effective than lifestyle modification in improving clinical symptoms and polysomnographic parameters, although NIV yielded better respiratory functional improvements than did CPAP. Long-term studies must demonstrate whether this functional improvement has relevant implications. Clinical trial registered with www.clinicaltrials.gov (NCT01405976).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.