Ex situ normothermic machine perfusion (NMP) might minimize ischemia/reperfusion injury (IRI) of liver grafts. In this study, 20 primary liver transplantation recipients of older grafts (≥70 years) were randomized 1:1 to NMP or cold storage (CS) groups. The primary study endpoint was to evaluate graft and patient survival at 6 months posttransplantation. The secondary endpoint was to evaluate liver and bile duct biopsies; IRI by means of peak transaminases within 7 days after surgery; and incidence of biliary complications at month 6. Liver and bile duct biopsies were collected at bench surgery, end of ex situ NMP, and end of transplant surgery. Interleukin (IL) 6, IL10, and tumor necrosis factor α (TNF-α) perfusate concentrations were tested during NMP. All grafts were successfully transplanted. Median (interquartile range) posttransplant aspartate aminotransferase peak was 709 (371-1575) IU/L for NMP and 574 (377-1162) IU/L for CS (P = 0.597). There was 1 hepatic artery thrombosis in the NMP group and 1 death in the CS group. In NMP, we observed high TNF-α perfusate levels, and these were inversely correlated with lactate (P < 0.001). Electron microscopy showed decreased mitochondrial volume density and steatosis and an increased volume density of autophagic vacuoles at the end of transplantation in NMP versus CS patients (P < 0.001). Use of NMP with older liver grafts is associated with histological evidence of reduced IRI, although the clinical benefit remains to be demonstrated. The use of very old donors in liver transplantation (LT)is showing favorable results, (1) but this practice is not universally implemented (2) because of concerns about a higher risk for primary nonfunction (PNF), delayed graft function (DGF), (3) and worse longterm graft survival. (4) In our recent series of octogenarian donors, we reported favorable overall longterm results, and we found that hepatitis C virus (HCV) recurrence and ischemic-type biliary lesions (ITBLs) were 2 independent causes of graft loss in this population. (5) Although availability of direct antiviral agents is reducing the impact of donor age on HCV recurrence, (6) prevention of ischemia/reperfusion injury (IRI) is pivotal to the practice of elderly donor LT and for donation after circulatory death (DCD) donors. (7,8) Even though the concept of the ideal donor is well defined, (4,9) the definition of extended criteria donors remains controversial. Increased donor age contributes to a higher risk ghinOlfi et al.
In Italy, 20 minutes of a continuous flat line on an electrocardiogram are required for declaration of death. In the setting of donation after circulatory death (DCD), prolonged warm ischemia time prompted the introduction of abdominal normothermic regional perfusion (NRP) followed by postprocurement ex situ machine perfusion (MP). This is a retrospective review of DCD liver transplantations (LTs) performed at 2 centers using sequential NRP and ex situ MP. From January 2018 to April 2019, 34 DCD donors were evaluated. Three (8.8%) were discarded before NRP, and 11 (32.4%) were discarded based on NRP parameters (n = 1, 3.0%), liver macroscopic appearance at procurement and/or biopsy results (n = 9, 26.5%), or severe macroangiopathy at back‐table evaluation (n = 1, 3.0%). A total of 20 grafts (58.8%; 11 uncontrolled DCDs, 9 controlled DCDs) were considered eligible for LT, procured and perfused ex situ (9 normothermic and 11 dual hypothermic MPs). In total, 18 (52.9%; 11 uncontrolled) livers were eventually transplanted. Median (interquartile range) no‐flow time was 32.5 (30‐39) minutes, whereas median functional warm ischemia time was 52.5 (47‐74) minutes (controlled DCD), and median low‐flow time was 112 minutes (105‐129 minutes; uncontrolled DCD). There was no primary nonfunction, while postreperfusion syndrome occurred in 8 (44%) recipients. Early allograft dysfunction happened in 5 (28%) patients, while acute kidney injury occurred in 5 (28%). After a median follow‐up of 15.1 (9.5‐22.3) months, 1 case of ischemic‐type biliary lesions and 1 patient death were reported. DCD LT is feasible even with the 20‐minute no‐touch rule. Strict NRP and ex situ MP selection criteria are needed to optimize postoperative results.
The use of machine perfusion (MP) in liver transplantation (LT) is spreading worldwide. However, its efficacy has not been demonstrated, and its proper clinical use has far to go to be widely implemented. The Società Italiana Trapianti d’Organo (SITO) promoted the development of an evidence‐based position paper. A 3‐step approach has been adopted to develop this position paper. First, SITO appointed a chair and a cochair who then assembled a working group with specific experience of MP in LT. The Guideline Development Group framed the clinical questions into a patient, intervention, control, and outcome (PICO) format, extracted and analyzed the available literature, ranked the quality of the evidence, and prepared and graded the recommendations. Recommendations were then discussed by all the members of the SITO and were voted on via the Delphi method by an institutional review board. Finally, they were evaluated and scored by a panel of external reviewers. All available literature was analyzed, and its quality was ranked. A total of 18 recommendations regarding the use and the efficacy of ex situ hypothermic and normothermic machine perfusion and sequential normothermic regional perfusion and ex situ MP were prepared and graded according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) method. A critical and scientific approach is required for the safe implementation of this new technology.
Use of elderly donors is not associated per se with an increased risk of vascular and biliary complications. In the presence of cold ischemia time and diabetes mellitus, appropriate donor-to-recipient matching is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.