Background—
Nonvalvular atrial fibrillation is the most common arrhythmia. Patients with nonvalvular atrial fibrillation are at increased risk of stroke; therefore, we evaluated the efficacy and safety of different approaches to prevent this major complication.
Methods and Results—
We conducted electronic database searches of phase III randomized controlled trials. The groups were novel oral anticoagulants, Watchman left atrial appendage occlusion device (DEVICE), and warfarin. Efficacy outcomes were stroke or systemic embolism, and all-cause mortality. Safety outcome was major bleeding and procedure-related complications. A subgroup analysis of the elderly population was done. We used random-effects model to compare pooled outcomes and tested for heterogeneity. Odds ratios (ORs) and 95% confidence intervals (CIs) were computed for each outcome. Seven randomized controlled trials (n=73 978) were included. There was a significant difference favoring novel oral anticoagulants for systemic embolism (OR, 0.84; 95% CI, 0.72–0.97;
P
=0.01), all-cause mortality (OR, 0.89; 95% CI, 0.84–0.94;
P
<0.001), and safety outcomes (OR, 0.79; 95% CI, 0.65–0.97;
P
=0.026) compared with warfarin. No difference was seen between DEVICE and warfarin for efficacy end points; however, DEVICE had more complications (OR, 1.85; 95% CI, 1.14–3.01;
P
=0.012). In the elderly (6 randomized controlled trials, n=30 699), systemic embolism was favored with novel oral anticoagulants over warfarin (OR, 0.77; 95% CI, 0.68–0.87;
P
≤0.001). No evidence of significant publication bias was found.
Conclusions—
Novel oral anticoagulants is superior to warfarin for stroke prevention in nonvalvular atrial fibrillation. This benefit was also observed in the elderly population. DEVICE is a reasonable noninferior alternative to warfarin for stroke prevention, but cautious use is essential given safety concerns.
Nationwide public health restrictions due to the coronavirus disease 2019 (COVID-19) pandemic have disrupted people's routine physical activities, yet little objective information is available on the extent to which physical activity has changed among patients with pre-existing cardiac diseases. Using remote monitoring data of 9,924 patients with pacemakers and implantable cardiac defibrillators (ICDs) living in New York City and Minneapolis/Saint Paul, we assessed physical activity patterns among these patients in 2019 and 2020 from January through October. We found marked declines in physical activity among patients with implantable cardiac devices during COVID-19-related restrictions and the reduction was consistent across age and sex subgroups. Moreover, physical activity among these vulnerable patients did not return to pre-restrictions levels several months after COVID-19 restrictions were eased. Our findings highlight the need to consider the unintended consequences of mitigation strategies and develop approaches to encourage safe physical activity during the pandemic.
BackgroundThe systolic variation of mitral regurgitation (MR) is a pitfall in its quantification. Current recommendations advocate using quantitative echocardiographic techniques that account for this systolic variation. While prior studies have qualitatively described patterns of systolic variation no study has quantified this variation.MethodsThis study includes 41 patients who underwent cardiovascular magnetic resonance (CMR) evaluation for the assessment of MR. Systole was divided into 3 equal parts: early, mid, and late. The MR jets were categorized as holosystolc, early, or late based on the portions of systole the jet was visible. The aortic flow and left ventricular stroke volume (LVSV) acquired by CMR were plotted against time. The instantaneous regurgitant rate was calculated for each third of systole as the difference between the LVSV and the aortic flow.ResultsThe regurgitant rate varied widely with a 1.9-fold, 3.4-fold, and 1.6-fold difference between the lowest and highest rate in patients with early, late, and holosystolic jets respectively. There was overlap of peak regurgitant rates among patients with mild, moderate and severe MR. The greatest variation of regurgitant rate was seen among patients with mild MR.ConclusionCMR can quantify the systolic temporal variation of MR. There is significant variation of the mitral regurgitant rate even among patients with holosystolic MR jets. These findings highlight the need to use quantitative measures of MR severity that take into consideration the temporal variation of MR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.