The inelastic neutron scattering induced γ-ray signal from 12C in an Inertial Confinement Fusion capsule is demonstrated to be an effective and general diagnostic for shell ablator areal density. Experimental acquisition of the time-integrated signal at 4.4 MeV using threshold detection from four gas Čerenkov cells provides a direct measurement of the 12C areal density near stagnation. Application of a three-dimensional isobaric static model of data acquired in a recent high neutron yield National Ignition Facility experimental campaign reveals two general trends: smaller remaining ablator mass at stagnation and higher shell density with increasing laser drive.
A new deuterium-tritium (D-T) fusion gamma-to-neutron branching ratio [3H(d,γ)5He/3H(d,n)4He] value of (4.2 ± 2.0) × 10−5 was recently reported by this group [Y. Kim et al. Phys. Rev. C (submitted)]. This measurement, conducted at the OMEGA laser facility located at the University of Rochester, was made for the first time using inertial confinement fusion (ICF) plasmas. Neutron-induced backgrounds are significantly reduced in these experiments as compared to traditional beam-target accelerator-based experiments due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ-ray detectors with fast temporal responses and inherent energy thresholds. It is expected that this ICF-based measurement will help resolve the large and long-standing inconsistencies in previously reported accelerator-based values, which vary by a factor of approximately 30. The reported value at ICF conditions was determined by averaging the results of two methods: (1) a direct measurement of ICF D-T γ-ray and neutron emissions using absolutely calibrated detectors and (2) a separate cross-calibration against the better known D-3He gamma-to-proton branching ratio [3He(d, γ)5Li/3He(d,p)4He]. Here we include a detailed explanation of these results, and introduce as a corroborative method an in-situ γ-ray detector calibration using neutron-induced γ-rays. Also, by extending the established techniques to two additional series of implosions with significantly different ion temperatures, we test the branching ratio dependence on ion temperature. The data show a D-T branching ratio is nearly constant over the temperature range 2–9 keV. These studies motivate further investigation into the 5He and 5Li systems resulting from D-T and D-3He fusion, respectively, and result in improved ICF γ-ray reaction history diagnosis at the National Ignition Facility.
The D-T gamma-to-neutron branching ratio (3 H(d,γ) 5 He/ 3 H(d,n) 4 He) has been determined at inertial confinement fusion (ICF) conditions, where the center-of-mass energy of 14-24 keV is lower than in previous accelerator-based experiments. A D-T branching ratio value of (4.2 ± 2.0)×10-5 was determined by averaging the results of two methods: 1) a direct measurement of ICF D-T γ-ray and neutron emissions using absolutely-calibrated detectors, and 2) a separate cross-calibration against the D-3 He gamma-to-proton branching ratio (3 He(d,γ) 5 Li/ 3 He(d,p) 4 He). Neutron-induced backgrounds are significantly reduced as compared to traditional beam-target accelerator-based experiments due to the short pulse nature of ICF implosions and the use of gas Cherenkov γ-ray detectors with fast temporal responses and inherent energy thresholds. These measurements of the D-T branching ratio in an ICF environment test several theoretical assumptions about the nature of A = 5 systems, including the dominance of the 3/2 + resonance at low energies, the presence of the broad first excited state of 5 He in the spectra, and the charge-symmetric nature of the capture processes in the mirror systems 5 He and 5 Li.
The purpose of this study is to leverage radioluminescence imaging for the development of an automated high-dose-rate (HDR) brachytherapy quality assurance (QA) system that enables simultaneous measurements of dwell position, dwell time, wire velocity, and relative source strength in a single test. The system consists of a radioluminescence phosphor sheet (a mixture of Gd2O2S:Tb and PDMS) positioned atop a HDR needle applicator, a complementary metal-oxide-semiconductor digital camera used to capture the emitted radioluminescence signals from the scintillator sheet, and an in-house graphical user interface for signal processing. The signal processing was used to extract source intensity, location, and elapsed time, yielding the final measurements on dwell position, dwell time, and wire velocity. The source strength relative to the well chamber calibration (in unit of Air-Kerma strength, Sk ) is measured by establishing a calibration curve that correlates Sk with the detector response. Validation experiments are performed using three customized treatment plans. With these plans, the dwell position and dwell time are verified for a range of 110.0 cm–117.5 cm and 2 s–16 s, respectively, and the linear correlation with Sk is demonstrated for the source strength varying between 28 348 U (cGy cm2 h−1) and 41 906 U. The wire velocity, i.e. the speed of the radioactive source averaged over the distance in between dwell positions, is calculated for various distances ranging from 5 mm to 50 mm. Results show that the mean deviations of the measured dwell position and dwell time are 0.1 mm (range from 0 to 0.2 mm) and 32.5 ms (range from 0 to 60.0 ms) with respect to the planned values, respectively, and the system response is highly linear with Sk ( R2 = 0.998). Moreover, the measured wire velocities are comparable to previously reported values. Benefitting from the compact hardware design and image processing algorithms, the system provides a practical, reliable, and comprehensive solution for HDR QA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.