Janssen Vaccines & Prevention BV, National Institutes of Health, Ragon Institute of MGH, MIT and Harvard, Henry M Jackson Foundation for the Advancement of Military Medicine, US Department of Defense, and International AIDS Vaccine Initiative.
Background Acute human immunodeficiency virus type 1 (HIV-1) infection is a major contributor to transmission of HIV-1. An understanding of acute HIV-1 infection may be important in the development of treatment strategies to eradicate HIV-1 or achieve a functional cure. Methods We performed twice-weekly qualitative plasma HIV-1 RNA nucleic acid testing in 2276 volunteers who were at high risk for HIV-1 infection. For participants in whom acute HIV-1 infection was detected, clinical observations, quantitative measurements of plasma HIV-1 RNA levels (to assess viremia) and HIV antibodies, and results of immunophenotyping of lymphocytes were obtained twice weekly. Results Fifty of 112 volunteers with acute HIV-1 infection had two or more blood samples collected before HIV-1 antibodies were detected. The median peak viremia (6.7 log10 copies per milliliter) occurred 13 days after the first sample showed reactivity on nucleic acid testing. Reactivity on an enzyme immunoassay occurred at a median of 14 days. The nadir of viremia (4.3 log10 copies per milliliter) occurred at a median of 31 days and was nearly equivalent to the viral-load set point, the steady-state viremia that persists durably after resolution of acute viremia (median plasma HIV-1 RNA level, 4.4 log10 copies per milliliter). The peak viremia and downslope were correlated with the viral-load set point. Clinical manifestations of acute HIV-1 infection were most common just before and at the time of peak viremia. A median of one symptom of acute HIV-1 infection was recorded at a median of two study visits, and a median of one sign of acute HIV-1 infection was recorded at a median of three visits. Conclusions The viral-load set point occurred at a median of 31 days after the first detection of plasma viremia and correlated with peak viremia. Few symptoms and signs were observed during acute HIV-1 infection, and they were most common before peak viremia. (Funded by the Department of Defense and the National Institute of Allergy and Infectious Diseases.)
Background The Ad26.COV2.S vaccine was highly effective against severe–critical coronavirus disease 2019 (Covid-19), hospitalization, and death in the primary phase 3 efficacy analysis. Methods We conducted the final analysis in the double-blind phase of our multinational, randomized, placebo-controlled trial, in which adults were assigned in a 1:1 ratio to receive single-dose Ad26.COV2.S (5×10 10 viral particles) or placebo. The primary end points were vaccine efficacy against moderate to severe–critical Covid-19 with onset at least 14 days after administration and at least 28 days after administration in the per-protocol population. Safety and key secondary and exploratory end points were also assessed. Results Median follow-up in this analysis was 4 months; 8940 participants had at least 6 months of follow-up. In the per-protocol population (39,185 participants), vaccine efficacy against moderate to severe–critical Covid-19 at least 14 days after administration was 56.3% (95% confidence interval [CI], 51.3 to 60.8; 484 cases in the vaccine group vs. 1067 in the placebo group); at least 28 days after administration, vaccine efficacy was 52.9% (95% CI, 47.1 to 58.1; 433 cases in the vaccine group vs. 883 in the placebo group). Efficacy in the United States, primarily against the reference strain (B.1.D614G) and the B.1.1.7 (alpha) variant, was 69.7% (95% CI, 60.7 to 76.9); efficacy was reduced elsewhere against the P.1 (gamma), C.37 (lambda), and B.1.621 (mu) variants. Efficacy was 74.6% (95% CI, 64.7 to 82.1) against severe–critical Covid-19 (with only 4 severe–critical cases caused by the B.1.617.2 [delta] variant), 75.6% (95% CI, 54.3 to 88.0) against Covid-19 leading to medical intervention (including hospitalization), and 82.8% (95% CI, 40.5 to 96.8) against Covid-19–related death, with protection lasting 6 months or longer. Efficacy against any severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection was 41.7% (95% CI, 36.3 to 46.7). Ad26.COV2.S was associated with mainly mild-to-moderate adverse events, and no new safety concerns were identified. Conclusions A single dose of Ad26.COV2.S provided 52.9% protection against moderate to severe–critical Covid-19. Protection varied according to variant; higher protection was observed against severe Covid-19, medical intervention, and death than against other end points and lasted for 6 months or longer. (Funded by Janssen Research and Development and others; ENSEMBLE ClinicalTrials.gov number, NCT04505722 .)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.