Dabigatran is an oral anticoagulant that is increasingly used for atrial fibrillation (AF). Presently, many authorities state that routine laboratory coagulation monitoring is not required. However, data have recently been published demonstrating that higher trough plasma dabigatran concentrations are associated with lower thromboembolic and higher haemorrhagic event rates. Using these data, we simulate a range of AF patients with varying risks for these events and derive a target range of trough plasma dabigatran concentrations (30-130 μg l
−1). Finally, we propose that a conventional screening coagulation assay, the thrombin time (TT), can be used to discern whether or not patients are within this range of dabigatran concentrations.
AimsDabigatran is largely cleared by renal excretion. Renal function is thus a major determinant of trough dabigatran concentrations, which correlate with the risk of thromboembolic and haemorrhagic outcomes. Current dabigatran dosing guidelines use the Cockcroft–Gault (CG) equation to gauge renal function, instead of contemporary equations including the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations employing creatinine (CKD-EPI_Cr), cystatin C (CKD-EPI_Cys) and both renal biomarkers (CKD-EPI_CrCys).MethodsA linear regression model including the dabigatran etexilate maintenance dose rate, relevant interacting drugs and genetic polymorphisms (including CES1), was used to analyse the relationship between the values from each renal function equation and trough steady-state plasma dabigatran concentrations.ResultsThe median dose-corrected trough steady-state plasma dabigatran concentration in 52 patients (38–94 years) taking dabigatran etexilate was 60 µg/L (range 9–279). The dose-corrected trough concentration in a patient on phenytoin and phenobarbitone was >3 standard deviations below the cohort mean. The CG, CKD-EPI_Cr, CKD-EPI_Cys and CKD-EPI_CrCys equations explained (R2, 95 % CI) 32 % (9–55), 37 % (12–60), 41 % (16–64) and 47 % (20–69) of the variability in dabigatran concentrations between patients, respectively. One-way analysis of variance (ANOVA) comparing the R2 values for each equation was not statistically significant (p = 0.74).DiscussionEstimates of renal function using the four equations accounted for 32–47 % of the variability in dabigatran concentrations between patients. We are the first to provide evidence that co-administration of phenytoin/phenobarbitone with dabigatran etexilate is associated with significantly reduced dabigatran exposure.Electronic supplementary materialThe online version of this article (doi:10.1007/s40268-014-0045-9) contains supplementary material, which is available to authorized users.
We performed a retrospective audit of cross-laboratory testing of desmopressin and factor concentrate therapy to assess the potential utility of supplementary testing using the PFA-100 with functional von Willebrand factor (VWF) activity testing. Data were evaluated for a large number of patients with von Willebrand disease of type 1, type 2A or type 2M, as well as a comparative subset of individuals with haemophilia or carriers of haemophilia. Laboratory testing comprised pre and postdesmopressin, or pre and postconcentrate, evaluation of factor VIII, VWF antigen (VWF:Ag) and VWF ristocetin cofactor activity as traditionally performed, supplemented with collagen-binding (VWF:CB) testing and PFA-100 closure times. In brief, both therapies tended to normalize VWF test parameters and closure times in individuals with type 1 von Willebrand disease, with the level of correction in closure times related to the level of normalization of VWF, particularly the VWF:CB. However, although occasional correction of closure times was observed in patients with type 2A or type 2M von Willebrand disease, these did not in general normalize PFA-100 closure times either with desmopressin or factor concentrate therapy. In these patients, improvement in closure times was more likely in those in whom VWF:CB values normalized or when VWF:CB/VWF:Ag ratios normalized. This study confirms that there is a strong relationship between the presenting levels of plasma VWF and PFA-100 closure times, and that the supplementary combination of PFA-100 and VWF:CB testing might provide added clinical utility to current broadly applied testing strategies limited primarily to VWF:Ag, VWF ristocetin cofactor and factor VIII:coagulant. Future prospective investigations are warranted to validate these relationships and to investigate their therapeutic implications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.