Culture positivity correlated directly with the duration of open exposure of the uncovered operating-room trays. Light traffic in the operating room appeared to have no impact on the contamination risk. Coverage of surgical trays with a sterile towel significantly reduced the contamination risk.
More than 200,000 people in the United States are diagnosed annually with compartment syndrome. This condition is commonly established based on clinical parameters. Determining its presence, however, can be challenging in obtunded patients or those with an altered mental status. A delay in diagnosis and treatment of these injuries can result in significant morbidity. Surgical release of the enveloping fascia remains the acceptable standard treatment for compartment syndrome. This article reviews the evaluation and treatment of compartment syndrome.
Background
The basic perineural catheter design has changed minimally since inception, with the catheter introduced through or over a straight needle. The U.S. Food and Drug Administration recently cleared a novel perineural catheter design comprising a catheter attached to the back of a suture-shaped needle that is inserted, advanced along the arc of its curvature pulling the catheter past the target nerve, and then exited through the skin in a second location. The authors hypothesized that analgesia would be noninferior using the new versus traditional catheter design in the first two days after painful foot/ankle surgery with a primary outcome of average pain measured with the Numeric Rating Scale.
Methods
Subjects undergoing painful foot or ankle surgery with a continuous supraparaneural popliteal-sciatic nerve block 5 cm proximal to the bifurcation were randomized to either a suture-type or through-the-needle catheter and subsequent 3-day 0.2% ropivacaine infusion (basal 6 ml/h, bolus 4 ml, lockout 30 min). Subjects received daily follow-up for the first four days after surgery, including assessment for evidence of malfunction or dislodgement of the catheters.
Results
During the first two postoperative days the mean ± SD average pain scores were lower in subjects with the suture-catheter (n = 35) compared with the through-the-needle (n = 35) group (2.7 ± 2.4 vs. 3.4 ± 2.4) and found to be statistically noninferior (95% CI, −1.9 to 0.6; P < 0.001). No suture-style catheter was completely dislodged (0%), whereas the tips of three (9%) traditional catheters were found outside of the skin before purposeful removal on postoperative day 3 (P = 0.239).
Conclusions
Suture-type perineural catheters provided noninferior analgesia compared with traditional catheters for continuous popliteal-sciatic blocks after painful foot and ankle surgery. The new catheter design appears to be a viable alternative to traditional designs used for the past seven decades.
Editor’s Perspective
What We Already Know about This Topic
What This Article Tells Us That Is New
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.