OBJECTIVES The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex™ hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS All consecutive patients [n = 88; median age 59 (49–67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex™ device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex™ hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
Background We investigated the impact of an elevated plasma volume status (PVS) in patients undergoing TAVI on early clinical safety and mortality and assessed the prognostic utility of PVS for outcome prediction. Materials and methods We retrospectively calculated the PVS in 652 patients undergoing TAVI between 2009 and 2018 at two centres. They were then categorized into two groups depending on their preoperative PVS (PVS ≤−4; n = 257 vs PVS>−4; n = 379). Relative PVS was derived by subtracting calculated ideal (iPVS = c × weight) from actual plasma volume (aPVS = (1 − haematocrit) × (a + (b × weight in kg)). Results The need for renal replacement therapy (1 (0.4%) vs 17 (4.5%); P = .001), re‐operation for noncardiac reasons (9 (3.5%) vs 32 (8.4%); P = .003), re‐operation for bleeding (9 (3.5%) vs 27 (7.1%); P = .037) and major bleeding (14 (5.4%) vs 37 (9.8%); P = .033) were significantly higher in patients with a PVS>−4. The composite 30‐day early safety endpoint (234 (91.1%) vs 314 (82.8%); P = .002) confirms that an increased preoperative PVS is associated with a worse overall outcome after TAVI. Conclusions An elevated PVS (>−4) as a marker for congestion is associated with significantly worse outcome after TAVI and therefore should be incorporated in preprocedural risk stratification.
OBJECTIVES Our goal was to develop a modified frozen elephant trunk (FET) prosthesis with a stented left subclavian artery (LSA) side branch for LSA connection and to perform preclinical testing in a human cadaver model. METHODS We measured aortic diameters, distance between and diameters of supra-aortic vessels and the distance from the LSA offspring to the level of the left vertebral artery offspring in 70 patients. Based on these measurements, a novel FET prosthesis was developed (Cryolife/Jotec, Hechingen, Germany) featuring a stented side branch for an intrathoracic LSA connection. The feasibility and ease of implantation were tested in 2 human cadaver models at the Anatomical Institute of the Medical University Graz. A covered stent graft (Advanta V12™ by Atrium Medical Corp., Hudson, NH, USA) was used for an LSA extension. RESULTS Accurate deployment of the novel FET prosthesis with anatomical orientation of the stented side branch towards the LSA ostium followed by consecutive stent graft deployment was feasible in both cases. Proximalizing the distal anastomosis level from zone 3 to zone 1 not only diminished the complexity of the procedure but substantially facilitated the completion of the distal anastomosis. A 2.5-cm long extension stent graft was sufficient to seal to the LSA and to maintain left vertebral artery patency in both cases. CONCLUSIONS This initial study in human anatomical bodies could demonstrate the feasibility of implanting a newly designed FET prosthesis. This evolution of the FET technique has the potential to substantially ease total aortic arch replacement by proximalization of the distal anastomosis into zone 1 and by shortening spinal and lower body hypothermic circulatory arrest times via a stented side branch to the LSA. This direct connection enables early restoration of systemic perfusion.
Transcatheter aortic valve replacement (TAVR) offers a novel treatment option for patients with severe symptomatic aortic valve stenosis, particularly for patients who are unsuitable candidates for surgical intervention. However, high therapeutical costs, socio-economic considerations, and numerous comorbidities make it necessary to target and allocate available resources efficiently. In the present study, we aimed to identify risk factors associated with futile treatment following transfemoral (TF) and transapical (TA) TAVR. Five hundred and thirty-two consecutive patients (82 ± 9 years, female 63%) who underwent TAVR between June 2009 and December 2016 at the Vienna Heart Center Hietzing were retrospectively analyzed to identify predictors of futility, defined as all-cause mortality at one year following the procedure for the overall patient cohort, as well as the TF and TA cohort. Out of 532 patients, 91 (17%) did not survive the first year after TAVR. A multivariate logistic model identified cerebrovascular disease, home oxygen dependency, wheelchair dependency, periinterventional myocardial infarction, and postinterventional renal replacement therapy as the factors independently associated with an increased one-year mortality. Our findings underscore the significance of a precise preinterventional evaluation, as well as illustrating the subtle differences in baseline characteristics in the TF and TA cohort and their impact on one-year mortality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.