Background-Thromboembolism due to atrial fibrillation (AF) is a frequent cause of stroke. More than 90% of thrombi in AF form in the left atrial appendage (LAA). Obliteration of the appendage may prevent embolic complications. Methods and Results-We evaluated the feasibility and safety of implanting a novel device for percutaneous left atrial appendage transcatheter occlusion (PLAATO). LAA occlusion using the PLAATO system was attempted in 15 patients with chronic AF at high risk for stroke, who are poor candidates for long-term warfarin therapy. The implant consists of a self-expanding nitinol cage covered with a polymeric membrane (ePTFE). The LAA was successfully occluded in 15/15 patients (100%). Angiography and transesophageal echocardiography (TEE) during the procedure showed that the device was well-seated in all patients and that there was no evidence of perforation, device embolization, or interference with surrounding structures. In 1 patient, the first procedure was complicated by a hemopericardium, which occurred during LAA access. A second attempt 30 days later was successful with no untoward sequela. No other complications occurred. At 1-month follow-up, chest fluoroscopy and TEE revealed continued stable implant position with smooth atrial-facing surface and no evidence of thrombus. Conclusions-Thus, transcatheter closure of the LAA is feasible in humans. This novel implant technology may be appropriate for patients with AF who are not suitable candidates for anticoagulation therapy. Further trials are needed to show the long-term safety and its efficacy in reducing stroke.
Paradoxical embolism through a patent foramen ovale (PFO) has been recognized as a potential cause of transient ischemia attack (TIA) and stroke especially in younger patients. The therapeutic options are medical treatment (antiaggregation or anticoagulation) with an annual recurrence rate of 3% to 4% for stroke or TIA, surgical PFO closure, or catheter closure. Randomized studies are ongoing; however, the results will not be available soon. Since August 1994, we have attempted catheter closure of a PFO in 281 patients (age 17 to 79 years, mean 46.8 +/- 13.2) with paradoxical embolism. Of these, 184 patients had at least one embolic stroke, 112 patients at least one TIA, and 15 patients at least one peripheral embolism. The diameter of the PFO, measured with a balloon catheter, ranged from 3 mm to 24 mm with a mean of 10 +/- 3.5 mm. Implantation of the occluder was technically successful in all patients (two attempts in four patients). Seven different devices were used: 26 Sideris buttoned, 11 ASDOS, 19 Angel Wings, 98 PFO-Star, 37 Cardioseal-Starflex, 57 Amplatzer and, 33 Helex devices. One patient suffered from septicemia and subsequently died. In 2 patients, device embolization occurred during or after the procedure (1 Sideris, 1 PFO-Star; catheter retrieval successful). Thirty-seven patients had other minor complications without long-term sequelae: atrial fibrillation within the first weeks after implantation in five patients, asymptomatic thrombus on the device at routine transesophageal echocardiogram (TEE) in 7 patients (1 Angel Wings, 1 ASDOS, 1 CardioSeal, 4 PFO-Star), and device frame fracture in 25 patients (2 Sideris, 4 ASDOS, 1 Angel Wings, 1 CardioSeal, 17 PFO-Star). No complications occurred with the newer devices (Amplatzer and Helex). A residual shunt after 6 months was found in 5.5% of the patients who had completed their 6-month TEE follow-up. In two patients, a second occluder was implanted because of a residual shunt. During a follow-up period of 1 month to 71 months (mean 12 +/- 16 months, 268 patient years), a recurrence of an embolic event (seven TIA, two stroke) occurred in eight patients. None of these occurred with the newer devices (Amplatzer, Helex). Freedom from recurrence of the combined end point of TIA, ischemic stroke, and peripheral embolism was 95.7% (95% CI: 89.0%-98.4%) at 1 year and 94.1% (95% CI: 80.1-98.4%) at 3 years. Catheter PFO closure is a technically simple procedure. With the newer devices and increasing experience, the success rate has improved and the complication rate has decreased. The advantage of the procedure is that closing the defect means a causal treatment. However, catheter closure of PFO despite a very low morbidity has inherent potential risks like any other interventional procedure. Furthermore, selection of patients who definitely have PFO as the cause of their cerebral event has not been defined. For these reasons, further studies are warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.