BackgroundThe independent prognostic impact of diabetes mellitus (DM) and prediabetes mellitus (pre‐DM) on survival outcomes in patients with chronic heart failure has been investigated in observational registries and randomized, clinical trials, but the results have been often inconclusive or conflicting. We examined the independent prognostic impact of DM and pre‐DM on survival outcomes in the GISSI‐HF (Gruppo Italiano per lo Studio della Sopravvivenza nella Insufficienza Cardiaca‐Heart Failure) trial.Methods and ResultsWe assessed the risk of all‐cause death and the composite of all‐cause death or cardiovascular hospitalization over a median follow‐up period of 3.9 years among the 6935 chronic heart failure participants of the GISSI‐HF trial, who were stratified by presence of DM (n=2852), pre‐DM (n=2013), and non‐DM (n=2070) at baseline. Compared with non‐DM patients, those with DM had remarkably higher incidence rates of all‐cause death (34.5% versus 24.6%) and the composite end point (63.6% versus 54.7%). Conversely, both event rates were similar between non‐DM patients and those with pre‐DM. Cox regression analysis showed that DM, but not pre‐DM, was associated with an increased risk of all‐cause death (adjusted hazard ratio, 1.43; 95% CI, 1.28–1.60) and of the composite end point (adjusted hazard ratio, 1.23; 95% CI, 1.13–1.32), independently of established risk factors. In the DM subgroup, higher hemoglobin A1c was also independently associated with increased risk of both study outcomes (all‐cause death: adjusted hazard ratio, 1.21; 95% CI, 1.02–1.43; and composite end point: adjusted hazard ratio, 1.14; 95% CI, 1.01–1.29, respectively).ConclusionsPresence of DM was independently associated with poor long‐term survival outcomes in patients with chronic heart failure.Clinical Trial Registration
URL: http://www.clinicaltrials.gov. Unique identifier: NCT00336336.
The present study examines the potential electromagnetic interference effects induced by cellular telephones on ICDs. We developed ad hoc protocols to conduct both in vitro and in vivo trials on most of the implantable cardioverter defibrillators available on the international market. Trials were conducted with three cellular telephones: two GSM (Global System for Mobile Communication) and one TACS (Total Access Communication System). A human trunk simulator was used to carry out in vitro observations on six ICDs from five manufacturers. In vivo tests were conducted on 13 informed patients with eight different ICD models. During the trials in air, GSM telephones induced interference effects on 4 out of the 6 cardioverter defibrillators tested. Specifically, pulse inhibition, reprogramming, false ventricular fibrillation, and ventricular tachycardia detections occurred, which would have entailed inappropriate therapy delivery had this been activated. Effects were circumscribed to the area closely surrounding the connectors. When the ICD was immersed in saline solution, no effects were observed. Three cases of just ventricular triggering with the interfering signal were observed in vivo.
Cannulation of CS with the adjunct of an electrophysiology catheter to dedicated delivery systems significantly reduces procedural time, fluoroscopy time and contrast dye volume compared to a conventional strategy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.