Many enveloped viruses induce multinucleated cells (syncytia), reflective of membrane fusion events caused by the same machinery that underlies viral entry. These syncytia are thought to facilitate replication and evasion of the host immune response. Here, we report that co-culture of human cells expressing the receptor ACE2 with cells expressing SARS-CoV-2 spike, results in synapse-like intercellular contacts that initiate cell-cell fusion, producing syncytia resembling those we identify in lungs of COVID-19 patients. To assess the mechanism of spike/ACE2-driven membrane fusion, we developed a microscopy-based, cell-cell fusion assay to screen ~6000 drugs and >30 spike variants. Together with quantitative cell biology approaches, the screen reveals an essential role for biophysical aspects of the membrane, particularly cholesterol-rich regions, in spike-mediated fusion, which extends to replication-competent SARS-CoV-2 isolates. Our findings potentially provide a molecular basis for positive outcomes reported in COVID-19 patients taking statins and suggest new strategies for therapeutics targeting the membrane of SARS-CoV-2 and other fusogenic viruses.
Carbene chemistry has been used recently in structural mass spectrometry as a labeling method for mapping protein surfaces. The current study presents a method for quantitating label distribution at the amino acid level and explores the nature and basis for an earlier observation of labeling bias. With the use of a method based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) applied to digests of holo-calmodulin, we developed a quantitation strategy to map site-specific incorporation of carbene, generated from photolysis of ionic label precursors 2-amino-4,4-azipentanoic acid and 4,4-azipentanoic acid. The approach provides reliable incorporation data for fragments generated by electron-transfer dissociation, whereas high-energy collisional dissociation leads to energy and sequence-dependent loss of the label as a neutral. However, both can produce data suitable for mapping residues in the interaction of holo-calmodulin with M13 peptide ligand. Site-specific labeling was monitored as a function of reagent, ionic strength, and temperature, demonstrating that electrostatic interactions at the protein surface can "steer" the distribution of label precursors to sites of surface charge and favor label insertion into residues in the vicinity of the surface charge. A further preference for insertion into carboxylates was observed, based on chemical reactivity. We suggest that decoupling surface partitioning from the chemistry of insertion offers a flexible, tunable labeling strategy for structural mass spectrometry that can be applied to a broad range of protein surface compositions and promotes the design of reagents to simplify the workflow.
We report a protein labeling method using nonselective carbene reactions of sufficiently high efficiency to permit detection by mass spectrometric methods. The approach uses a diazirine-modified amino acid (l-2-amino-4,4'-azipentanoic acid, "photoleucine") as a label source, which is converted to a highly reactive carbene by pulsed laser photolysis at 355 nm. Labeling of standard proteins and peptides (CaM, Mb, M13) was achieved with yields up to 390-fold higher than previous studies using methylene. Carbene labeling is sensitive to changes in protein topography brought about by conformational change and ligand binding. The modification of apo-CaM was 45 ± 7% higher than that of holo-CaM. Modification of the CaM-M13 complex reflected a 39 ± 1% reduction in labeling for bound holo-CaM relative to free holo-CaM. Labeling yield is independent of protein concentration over approximately 2 orders of magnitude but is weakly dependent on the presence of other chromophores in a photon-limited apparatus. The current configuration required 2 min of irradiation for full reagent conversion; however, it is shown that comparable yields can be achieved with a single high-energy laser pulse (>100 mJ/pulse, <10 ns), offering a labeling method with high temporal resolution. We suggest a mechanism of labeling governed by limited carbene diffusion and the protein surface activity of the diazirine precursor. This surface activity is speculated to return a measure of selectivity relative to methylene labeling, which ultimately may be tunable.
Broadband transient absorption and two-dimensional electronic spectroscopy (2DES) studies of methylene blue in aqueous solution are reported. By isolating the coherent oscillations of the nonlinear signal amplitude and Fourier transforming with respect to the population time, we analyzed a significant number of coherences in the frequency domain and compared them with predictions of the vibronic spectrum from density function theory (DFT) calculations. We show here that such a comparison enables reliable assignments of vibrational coherences to particular vibrational modes, with their constituent combination bands and overtones also being identified via Franck–Condon analysis aided by DFT. Evaluation of the Fourier transform (FT) spectrum of transient absorption recorded to picosecond population times, in coincidence with 2D oscillation maps that disperse the FT spectrum into the additional excitation axis, is shown to be a complementary approach toward detailed coherence determination. Using the Franck–Condon overlap integrals determined from DFT calculations, we modeled 2D oscillation maps up to two vibrational quanta in the ground and excited state (six-level model), showing agreement with experiment. This semiquantitative analysis is used to interpret the geometry change upon photoexcitation as an expansion of the central sulfur/nitrogen containing ring due to the increased antibonding character in the excited state.
We rebuild the theory of ultrafast transient-absorption/transmission spectroscopy starting from the optical response of an individual molecule to incident femtosecond pump and probe pulses. The resulting description makes use of pulse propagators and free molecular evolution operators to arrive at compact expressions for the several contributions to a transient-absorption signal. In this alternative description, which is physically equivalent to the conventional response-function formalism, these signal contributions are conveniently expressed as quantum mechanical overlaps between nuclear wave packets that have undergone different sequences of pulse-driven optical transitions and time-evolution on different electronic potential-energy surfaces. Using this setup in application to a simple, multimode model of the light-harvesting chromophores of PC577, we develop wave-packet pictures of certain generic features of ultrafast transient-absorption signals related to the probed-frequency dependence of vibrational quantum beats. These include a Stokes-shifting node at the time-evolving peak emission frequency, antiphasing between vibrational oscillations on opposite sides (i.e., to the red or blue) of this node, and spectral fingering due to vibrational overtones and combinations. Our calculations make a vibrationally abrupt approximation for the incident pump and probe pulses, but properly account for temporal pulse overlap and signal turn-on, rather than neglecting pulse overlap or assuming delta-function excitations, as are sometimes done.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.