AimControversy exists concerning the relation between Helicobacter pylori (HP) infection and coronary artery disease (CAD). We aimed to examine the relationship between HP infection and severity of coronary atherosclerosis in patients with chronic CAD.Patients and methodsA total of 150 patients (109 [73%] men; mean age 62.61±10.23 years) scheduled for coronary artery bypass grafting surgery were consecutively enrolled in the cross-sectional study. According to rapid urease test and/or gastric biopsy samples stained with hematoxylin and eosin and according to Giemsa, patients were classified as HP positive (n=87; 58%) or HP negative (n=63; 42%). Coronary angiograms were scored by quantitative assessment, using multiple angiographic scoring system: 1) vessel score (number of coronary arteries stenosed ≥50%), 2) Gensini score (assigning a severity score to each coronary stenosis according to the degree of luminal narrowing and its topographic importance) and 3) angiographic severity score (number of coronary artery segments stenosed ≥50%).ResultsIn comparison to HP-negative patients, HP-positive patients were more frequently hypertensive (P=0.014), had higher values of systolic (P=0.043) and diastolic (P=0.005) blood pressure and total cholesterol (P=0.013) and had lower values of high-density lipoprotein-cholesterol (HDL-C; P=0.010). There were no significant differences between the groups in the severity of coronary atherosclerosis: vessel score (P=0.152), Gensini score (P=0.870) and angiographic severity score (P=0.734).ConclusionIt is likely that HP infection is not a risk factor for the severity of coronary atherosclerosis in chronic CAD patients.
Background: Our aim was to determine the effectiveness of a new surgical technique for olecranon fractures using a tension plate (TP) designed by the operating surgeon.
Methods:We included patients with olecranon fractures treated between September 2010 and August 2013 in our study. Treatment involved a new implant and operative technique, which combined the most favourable characteristics of 2 frequently used methods, tension band wiring and plate osteosynthesis, while eliminating their shortcomings. The new method was based on the newly constructed implant.Results: Twenty patients participated in our study. We obtained the following functional results with our TP: median flexion 147.5° (interquartile range [IQR] 130°-155°), median extension 135°/deficit 10° (IQR 135°-145°), median pronation 90° (IQR 81.3°-90°), median supination 90° (IQR 80°-90°). Implant-related complications were noted in 1 patient, and implants were removed in 3 patients. The mean functional Mayo elbow performance score was 94.8 (range 65-100). The removal of the implant was considerably less frequent in patients operated using the new method and implant than in patients operated using conventional methods at our institution (p < 0.001). Mean duration of follow-up was 8 months.
Conclusion:Our TP for the treatment of olecranon fractures is safe and effective. Functional results are very good, with significantly decreased postoperative inconveniences and need to remove the implant. Less osteosynthetic material was used for TP construction, but stability was preserved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.