Objectives. It was the aim of this study to determine thermal and histologic events resulting from soft tissue incision with three C02 lasers: one emitting light energy via a hollow waveguide at 9.3 #m; the others emitting light energy at 10.6/~m, one via a hollow waveguide, the other through an articulated arm delivery system. Study design. Thirty standardized incisions were made in the oral mucosa of pig's mandibles with three different lasers at actual power levels of 1,4, and 12 W. Thermal events were recorded with thermocouples, and a histologic examination was performed to determine vertical and horizontal tissue damage as well as incision depth and width.Results. Thermal and histologic results were related to parameters andbeam characteristics rather than wavelength. Conclusion. In addition to wavelength, many variables can contribute to the surgical characteristics of a laser.(ORAL SURG ORAL MED ORAL PATHOL ORAL RADIOL IENDOD 1995;79:685-91)
Dentin was visualized using a new fluorescence technique and confocal laser scanning microscopy. Thirty extracted human teeth showing no clinical signs of caries were investigated. All teeth were horizontally sectioned to approximately 200 m thickness and sections were subjected to different pretreatment conditions as follows: vacuum only, ultrasonication only, sodium hypochlorite only, sodium hypochlorite and vacuum, sodium hypochlorite and ultrasonication, and a combination of sodium hypochlorite, vacuum, and ultrasonication. Some samples were left untreated to serve as control. Following pretreatment, rhodamine 123 fluorescent dye was used for staining at concentrations ranging from 10 Ϫ3 to 10 Ϫ7 M for 1 to 24 h at pH 6.0, 6.5, or 7.4. Optical staining occurred at pH 7.4 and concentrations у 10 Ϫ5 M over 3 h or longer. Surface images obtained using confocal laser scanning microscopy were similar to those observed by scanning electron microscopy without the need for sample-altering conventional scanning electron microscope preparation techniques. Subsurface imaging to a depth of approximately 60 m was achieved using confocal laser microscope techniques. This fluorescence technique offers a useful new alternative for visualization and quantification of dentin.
We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality ofa tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induce pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back-scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent ofthe sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.