Lateral sided hip pain frequently presents to the orthopaedic clinic. The most common cause of this pain is trochanteric bursitis. This usually improves with conservative treatment. In a few cases it doesn't settle and warrants further investigation and treatment. We present a series of 28 patients who underwent MRI scanning for such pain, 16 were found to have a tear of their abductors. All 16 underwent surgical repair using multiple soft tissue anchors inserted into the greater trochanter of the hip to reattach the abductors. There were 15 females and 1 male. All patients completed a self-administered questionnaire pre-operatively and 1 year post-operatively. Data collected included: A visual analogue score for hip pain, Charnley modification of the Merle D'Aubigne and Postel hip score, Oxford hip score, Kuhfuss score of Trendelenburg and SF36 scores.Of the 16 patients who underwent surgery 5 had a failure of surgical treatment. There were 4 re ruptures, 3 of which were revised and 1 deep infection which required debridement. In the remaining 11 patients there were statistically significant improvements in hip symptoms. The mean change in visual analogue score was 5 out of 10 (p=0.0024) The mean change of Oxford hip score was 20.5 (p=0.00085). The mean improvement in SF-36 PCS was 8.5 (P=0.0020) and MCS 13.7 (P=0.134). 6 patients who had a Trendelenburg gait pre-surgery had normal gait 1 year following surgery.We conclude that hip abductor mechanism tear is a frequent cause of recalcitrant trochanteric pain that should be further investigated with MRI scanning. Surgical repair is a successful operation for reduction of pain and improvement of function. However there is a relatively high failure rate.
BackgroundScaphoid fractures account for 90% of carpal fractures and occur predominantly in young men. Immediate surgical fixation of this fracture has increased, in spite of insufficient evidence of improved outcomes over non-surgical management. We compared the clinical effectiveness of surgical fixation with cast immobilization and early fixation of those that fail to unite, for ≤2 mm displaced scaphoid waist fractures in adults. MethodsThis pragmatic, multicentre, open-label, parallel-group, two-arm randomised clinical trial included adults who presented to orthopaedic departments of 31 hospitals in England and Wales with a clear, bicortical fracture of the scaphoid waist on radiographs. Participants were randomly assigned to early surgical fixation or below-elbow cast immobilization followed by immediate fixation of confirmed non-union. The primary outcome was the Patient Rated Wrist Evaluation (PRWE) total score at 52 weeks post-randomisation. Registration ISRCTN67901257. FindingsOf 439 randomised patients (mean age 33 years, 363 [83%] men), 408 (93%) were included in the primary analyses. There was no difference in PRWE score at 52 weeks (adjusted mean difference -2•1 points, 95% CI -5•8 to 1•6, p=0•27). There were no differences at 52 weeks for the PRWE pain or function subscales. More participants in the surgery group experienced a surgery-related potentially serious complication than in the cast group (n=31, 14% vs n=3, 1%), but fewer had cast-related complications (n=5, 2% vs n=40, 18%). The number experiencing a medical complication (n=4, 2% vs n=5, 2%) was similar in the two groups." InterpretationAdult patients with ≤2 mm displaced scaphoid waist fracture should have initial cast immobilization and suspected non-unions confirmed and immediately fixed. This will help avoid risks of surgery and mostly limit its use to fixing non-union.
The use of robots in orthopaedic surgery is an emerging field that is gaining momentum. It has the potential for significant improvements in surgical planning, accuracy of component implantation and patient safety. Advocates of robot-assisted systems describe better patient outcomes through improved pre-operative planning and enhanced execution of surgery. However, costs, limited availability, a lack of evidence regarding the efficiency and safety of such systems and an absence of long-term high-impact studies have restricted the widespread implementation of these systems. We have reviewed the literature on the efficacy, safety and current understanding of the use of robotics in orthopaedics.
Between 1986 and 1991 we implanted 331 consecutive Furlong hydroxyapatite-coated femoral components of a total hip replacement in 291 patients. A cemented acetabular prosthesis was used in 217 hips and a hydroxyapatite-coated component in 114. We describe the long-term clinical and radiological survival of the femoral component at a mean follow-up of 17.5 years (15 to 21). Only two patients (0.68%) were lost to follow-up. With revision of the femoral component for any reason as the endpoint, the survival at a mean of 17 years was 97.4% (95% confidence interval 94.1 to 99.5), and with revision for aseptic loosening as the endpoint it was 100%. The survival at a maximum of 21 years with revision of the femoral component for any reason as the endpoint was 97.4% (95% confidence interval 81.0 or 99.5). These results compare favourably with the best long-term results of cemented or uncemented femoral components used in total hip replacement.
NOTES distal pancreatectomy is technically feasible in the porcine model. The transvaginal approach provides a vantage point very similar to that of the transcolonic route and holds promise as a NOTES access site, either singly or as part of a dual-lumen approach. The endoscopic linear stapler and R-scope both advance NOTES capabilities. The novel concepts of fully prone positioning, pneumodissection, and endoloop colotomy closures are introduced. Considering anatomical differences and that healthy animals were used, transferring this technique to patients with pancreatic disease might be difficult and further modifications would likely be needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.