Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force‐sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force‐time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8‐179] vs 199 [178.5‐227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5‐35.8] vs 43.2 [35.1‐52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 Ω, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group ( P = 0.186). Conclusion High‐powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
There is an increased recognition in the field of toxicology of the value of medium-to-high-throughput screening methods using in vitro and alternative animal models. We have previously introduced the asexual freshwater planarian Dugesia japonica as a new alternative animal model and proposed that it is particularly well-suited for the study of developmental neurotoxicology. In this paper, we discuss how we have expanded and automated our screening methodology to allow for fast screening of multiple behavioral endpoints, developmental toxicity, and mortality. Using an 87-compound library provided by the National Toxicology Program (NTP), consisting of known and suspected neurotoxicants, including drugs, flame retardants, industrial chemicals, polycyclic aromatic hydrocarbons (PAHs), pesticides and presumptive negative controls, we further evaluate the benefits and limitations of the system for medium-throughput screening, focusing on the technical aspects of the system. We show that, in the context of this library, planarians are the most sensitive to pesticides with 16/16 compounds causing toxicity and the least sensitive to PAHs, with only 5/17 causing toxicity. Furthermore, while none of the presumptive negative controls were bioactive in adult planarians, 2/5, acetaminophen and acetylsalicylic acid, were bioactive in regenerating worms. Notably, these compounds were previously reported as developmentally toxic in mammalian studies. Through parallel screening of adults and developing animals, planarians are thus a useful model to detect such developmental-specific effects, which was observed for 13 chemicals in this library. We use the data and experience gained from this screen to propose guidelines for best practices when using planarians for toxicology screens.
Background Noninvasive mapping identifies potential drivers (PDs) in atrial fibrillation (AF). We analyzed the impact of pulmonary vein isolation (PVI) on PDs and whether baseline PD pattern predicted termination of AF. Methods Patients with persistent AF less than 2 years underwent electrocardiographic imaging mapping before and after cryoballoon PVI. We recorded the number of PD occurrences, characteristics (rotational wavefronts ≥ 1.5 revolutions or focal activations), and distribution using an 18‐segment atrial model. Results Of 100 patients recruited, PVI terminated AF in 15 patients; 21.3% ± 9.1% (8.7 ± 4.8) of PDs occurred at the pulmonary veins (PVs) and posterior wall. PVI had no impact on PD occurrences outside the PVs and posterior wall (33.2 ± 12.9 vs 31.6 ± 12.5; P = .164), distribution over the remaining 13 segments (9 [8‐11] vs 9 [8‐10]; P = .634), the proportion of PDs that was rotational (82.9% ± 9.7% vs 83.6% ± 10.1%; P = .496), or temporal stability (2.4 ± 0.4 vs 2.4 ± 0.5 rotations; P = .541). Fewer focal PDs (area under the curve, 0.683; 95% CI, 0.528‐0.839; P = .024) but not rotational PDs (P = .626) predicted AF termination with PVI. Conclusions PVI did not have a global impact on PDs outside the PVs and posterior wall. Although fewer focal PDs predicted termination of AF with PVI, the burden of rotational PDs did not. It is accepted though not all PDs are necessarily real or important. Outcome data are needed to confirm whether noninvasive mapping can predict patients likely to respond to PVI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.