COVID-19 outbreak had a major impact on the organization of care in Italy, and a survey to evaluate provision of for arrhythmia during COVID-19 outbreak (March-April 2020) was launched. A total of 104 physicians from 84 Italian arrhythmia centres took part in the survey. The vast majority of participating centres (95.2%) reported a significant reduction in the number of elective pacemaker implantations during the outbreak period compared to the corresponding two months of year 2019 (50.0% of centres reported a reduction of > 50%). Similarly, 92.9% of participating centres reported a significant reduction in the number of implantable cardioverter-defibrillator (ICD) implantations for primary prevention, and 72.6% a significant reduction of ICD implantations for secondary prevention (> 50% in 65.5 and 44.0% of the centres, respectively). The majority of participating centres (77.4%) reported a significant reduction in the number of elective ablations (> 50% in 65.5% of the centres). Also the interventional procedures performed in an emergency setting, as well as acute management of atrial fibrillation had a marked reduction, thus leading to the conclusion that the impact of COVID-19 was disrupting the entire organization of health care, with a massive impact on the activities and procedures related to arrhythmia management in Italy.
Our results confirm the limited value of QRS duration in the selection of patients for CRT. A less-advanced stage of disease and echocardiographic evidence of interventricular dyssynchrony demonstrated to predict response to CRT, while intraventricular dyssynchrony did not predict response.
To evaluate the safety and efficacy of a new algorithm for automatic mode switching (AMS) from DDD-DDDR to DDIR, 26 patients, 16 females and 10 males, mean age 73 +/- 6 years of age, affected by sinus node disease, chronotropic incompetence, and recurrent paroxysmal atrial fibrillation (PAF) received the Medtronic Thera DR pacemaker. The device continuously calculates, in ms, the running average of the intrinsic atrial rate (MAR) and compares the current atrial interval (CAI) with the stored MAR. When the CAI is greater than the MAR it increases by 8 ms, and when the CAI is less than the MAR, it decreases by 23 ms. When MAR < or = 330 ms (182 beats/min), tachycardia is detected and AMS is activated. All patients had clinical evaluation, 12-lead ECG, Holter monitoring, and exercise testing after implantation and every 3 months for 1 year. The results were compared with the data stored in the pacemaker memory: AMS episodes number; the histogram of the last 14 episodes; and atrial electrogram recording. Twenty-two Holter recordings in 13 patients showed PAF and in all of them AMS occurred simultaneously. AMS lasted between 10 seconds and 20 hours, and MAR ranged from 195-400 beats/min. No episode of PAF and no AMS were recorded in 39 Holter recordings in 22 patients. Appropriate AMS was confirmed in five patients by stored atrial electrogram and in nine by 12-lead ECG and pacemaker event markers. Mean atrial sensing was 2.13 +/- 1.04 mV during PAF and 3.18 +/- 1.46 mV during sinus rhythm. No PAF episode and no AMS were recorded during exercise testing. In conclusion, this new algorithm was very reliable, sensitive, and specific.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.