The Main Injector project at Fermilab requires B dipole with good field quality from 0.1 T to 1.73 T with ramps to full field at up to 2.4 T/s over an aperture of 10x6 cm. Op e&ion of this magnet for the variety of purposa proposed for the Main lqjector results in a design with low indnctame, large copper cnm metion, and fidd uniformity sufficient for high intensity iqjection and efficient slow resonant extraction. The resulting design is presented, along with meaauremcnt results of a prototype magnet emphasiring the field uniformity.
The Fermilab Main Injector Project will provide 120-150 GeV Proton and Antiproton Beams for Fez&lab Fiied Target Physics and Colliding Beams Physics use. A dipole magnet has been designed and prototypes constructed for the principal bending magnets of tbia new accelerator. The design considerations and fabrication techniquea are described. Mcasnnmcat results on prototypea arc reported, emphasising the field uniformity achieved in both body field and end field at excitation levels from injection at 0.1 T to full field of 1.7 T.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.