Effective compliance (time spent at the effective pressure) with nasal CPAP in obstructive sleep apnea has been reported to be poor. The aim of our study was to evaluate effective compliance in a large European multicenter study. One hundred twenty-one consecutive newly treated patients (initial apnea-hypopnea index [AHI] = 62.0 +/- 29. 5/h, AHI under CPAP = 6.4 +/- 8.1/h, CPAP pressure = 8.7 +/- 2.6 cm H(2)O, BMI = 33.1 +/- 6.8 kg/m(2)) were randomly allocated to a group with (MC(+)) (n = 58) or without (MC(-)) (n = 63) a control unit measuring effective compliance at 1, 2, and 3 mo, which was compared with the built-in time counter data. MC(+) data were 94 +/- 10, 98 +/- 5, and 96 +/- 9% of counter data at 1, 2, and 3 mo, respectively. Using criteria of regular use already reported in the literature (at least 4 h of nCPAP per day of use and nCPAP administered more than 70% of the days) we found 77, 82, and 79% compliant patients at 1, 2, and 3 mo, respectively, 79% of the patients meeting these criteria each month. Although there were no pulmonary functions or polysomnographic differences between the two subgroups, the compliant patients did report a greater improvement in minor symptoms. We found a close correlation between effective use of CPAP and the machine run time. The main result of our study was a higher effective compliance than previously reported, approximately 80% of the patients being regular users versus 46% in a previously published study. This may result from different technical and medical follow-up.
ResMed Autoset (AS) is a simplified diagnosis system for obstructive sleep apnoea/hypopnoea syndrome (OSAS) based on the respiratory flow/time relationship by pressure variation measured through simple nasal prongs. A multicentre prospective trial was used to compare AS and polysomnography (PSG) for diagnosing 95 patients, with suspected OSAS. Physicians gave a pretest probability of the patient having OSAS. The apnoea/hypopnoea index (AHI) was compared between the two methods of diagnosis for the whole population and for subgroups according to the pretest probability. Twenty-four patients had AHI < 15 events x h(-1) on PSG and 19 AHI 15-30, and 52 patients had AHI > or = 30. Correlation between AHI assessed by AS and PSG was r=0.87 for total sleep time (TST), p<0.0001. A Bland and Altman plot gave an agreement between the two methods of +/-40%. For a threshold of AHI > or = 15 events x h(-1) to diagnose OSAS, AS has a sensitivity of 92%, specificity of 79%, positive predictive value of 93% and negative predictive value of 76%. With a pretest probability > or = 80%, sensitivity and positive predictive value were 98 and 100% respectively. Of six false negative, four had a high pretest probability (> 80%) or Epworth score > or = 10. Using these parameters as a criterion for proceeding to PSG after a negative AS study would mean that two apnoeic patients (AHI 20 and 17 events x h(-1) by PSG) would escape detection. The Autoset is useful for the detection of obstructive sleep apnoea but with high pretest probability and a negative Autoset result polysomnography should be performed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.