We have undertaken a prospective clinical and radiological analysis of 124 shoulder arthroplasties (113 patients) carried out for osteoarthritis. The clinical results showed improvement in the absolute Constant score and the American Shoulder and Elbow Surgeons score of 22 and 43, respectively. Both were statistically significant (p < 0.001). There was no significant difference in the scores after hemiarthroplasty and total arthroplasty in those patients with an intact rotator cuff. When revision was used as the end-point for survival at ten years, survival of 86%, or 90% if glenoid components made of Hylamer sterilised in air were omitted, was obtained in primary osteoarthritis. The most common cause for revision in the hemiarthroplasty group was glenoid pain at a mean of 1.5 years; in the total arthroplasty group it was loosening of the glenoid at a mean of 4.5 years. Analysis of pre-operative factors showed that the risk of gross loosening of the glenoid increased threefold when there was evidence of erosion of the glenoid at operation. Shoulder arthroplasty should not be delayed once symptomatic osteoarthritis has been established and should be undertaken before failure of the cuff or erosion of the glenoid are present.
Aims: To evaluate the efficacy and safety of nitrous oxide-oxygen for children with juvenile idiopathic arthritis (JIA) undergoing intra-articular corticosteroid injection. Methods: A total of 55 consecutive patients with JIA undergoing intra-articular corticosteroid injection, using self administered nitrous oxide-oxygen for analgesia were studied. Patient, nurse, and parent pain scores were compared using a 0-10 cm visual analogue scale (VAS) immediately after the procedure. Results: A total of 70 joints were injected in 55 patients (median age 13.54 years). The median pain score for patient, nurse, and parent was 1 (0-10 cm VAS). The mean rank patient score was 2.12, which was greater than the nurse score (1.97), which was greater than the parent score (1.91). These differences were significant. There were no serious adverse events in any patient. Conclusions: Nitrous oxide-oxygen provides safe and effective analgesia for intra-articular injection in children. In some cases, nurses and parents underestimated pain related to the procedure compared to the child.
The MatOrtho proximal interphalangeal replacement is a cementless cobalt-chromium metal-on-polyethylene mobile-bearing surface replacement arthroplasty. The aim of this study is to report the outcome and complications of this implant at a minimum of 2 years follow-up from a single institution. A retrospective case review was performed on all MatOrtho proximal interphalangeal joint replacements performed with a minimum of 2 years follow-up. Patient demographics, diagnosis, implant revision and other surgical interventions were recorded. Subjective and objective outcomes were evaluated at latest follow-up, including pain scores, range of motion, function and radiographic assessment. A total of 109 implants were inserted in 56 patients. Nine implants (six patients) were lost to follow-up. Of the remaining 100 implants, 75 had been undertaken in females. The mean age at time of surgery was 64 years and the principal diagnosis was osteoarthritis in 74%. The mean follow-up was 47 months (range 24-77). Within the group there was a statistically significant diminution in pain. There was also an improvement in functional scores post-operatively. Improvement in range of motion was seen in those joints with a pre-operative range of motion greater than 20°. Radiologically there was no evidence of loosening or of implant subsidence at final follow-up. The revision rate was 13%. Nine joints were revised to the NeuFlex (silicone rubber) prosthesis, three were converted to an arthrodesis and one had exchange of the MatOrtho prosthesis. The survival of the MatOrtho proximal interphalangeal joint arthroplasty was 85% at a minimum of 2-years follow-up. Patients can be advised that the procedure achieves good pain relief, improvement in functional scores and may improve range of motion. We would, however, caution against this implant's use in joints that are either stiff or have significant deformity and/or instability pre-operatively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.