2019
DOI: 10.37358/mp.19.3.5218
|View full text |Cite
|
Sign up to set email alerts
|

Wear Resistance Under High Load Forces of Four Different Polyethylene Terephthalate Glycol Vacuum-Formed Orthodontic Retainers

Abstract: The aim of our study was to determine the wear resistance of vacuum-formed retainers (VFRs) made out of polyethylene terephthalate glycol (PETG), from four different manufacturers (Essix, Leone, Erkodent, Bio-Art), under high load forces (600 N), for 10000 cycles. Forty thermoplastic sheets were divided in four groups, each group consisting of a set of ten sheets from each manufacturer, thermoformed on two matching study models with an ideal occlusion. The Instron 8874 equipment was used to simulate the accele… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 9 publications
(12 reference statements)
0
7
0
Order By: Relevance
“…[ 12 ] tested PP and PETG in a thermoformed state using a stone block (76 × 50 × 38 mm) followed by use of a two-body wear machine with steatite balls under a load of 25 kg for 1000 cycles of wear. Bratu et al [ 13 ] used a custom jig, and upper and lower stone study models with retainers in place fixated on a metal plate with screws under a load of 61.2 kg for 10,000 cycles. The steatite ball possesses a hardness similar to tooth enamel (Mohs scale, 7.5) and is therefore more likely to induce a representative amount of wear on the thermoplastic material better simulating the intra-oral environment and related cycling.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[ 12 ] tested PP and PETG in a thermoformed state using a stone block (76 × 50 × 38 mm) followed by use of a two-body wear machine with steatite balls under a load of 25 kg for 1000 cycles of wear. Bratu et al [ 13 ] used a custom jig, and upper and lower stone study models with retainers in place fixated on a metal plate with screws under a load of 61.2 kg for 10,000 cycles. The steatite ball possesses a hardness similar to tooth enamel (Mohs scale, 7.5) and is therefore more likely to induce a representative amount of wear on the thermoplastic material better simulating the intra-oral environment and related cycling.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, Bratu et al . [ 13 ] found Duran to have 549-μm median wear in the lower arch. More significant wear levels in the latter study may relate to the increase in the load used (61.2 kg) and a higher number of cycles (10,000).…”
Section: Discussionmentioning
confidence: 99%
“…The removable retainers are efficient in the orthodontic practice in terms of maintaining the stability of the result of the active orthodontic treatment. They have many advantages related to the possibility of maintaining proper oral hygiene [ 37 ], are easy to perform [ 38 ], are acceptable in terms of aesthetics (especially the VFRs), and have a satisfactory resistance [ 39 ]. Their main disadvantage is related to the need for optimal collaboration of the patient.…”
Section: Discussionmentioning
confidence: 99%
“…Another FDM-compatible material, polyethylene terephthalate glycol (PETG), is gaining popularity in recent times. PETG is a glycol-modified version of polyethylene terephthalate (PET) [ 35 ] having high toughness, chemical resistance, durability, low forming temperature and, hence, proving to be a good material for thermoforming [ 36 ], extrusion, injection molding and FDM [ 36 , 37 , 38 , 39 , 40 ]. In recent times, PETG has found applications in medical industries, food packaging industries, electronics, etc.…”
Section: Introductionmentioning
confidence: 99%