2021
DOI: 10.1002/aisy.202100056
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: Wearable sensors with water resistance and mechanical durability are of great value in dealing with long‐term movement and remote control in harsh environments. However, achieving high sensitivity with long‐term stability and real‐time remote control in a watery environment is still a challenge. Herein, the waterproof wearable sensors with good mechanical robustness composed of laser‐induced graphene and in situ‐coated protective silicone layers are reported. By being integrated with high‐capacitance ion‐gel d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
28
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 28 publications
(28 citation statements)
references
References 58 publications
0
28
0
Order By: Relevance
“…As shown in Figure 2 g, the flexible triboelectric sensing array comprises a touch panel with 9-digital channels based on a LIG-patterned TENG [ 58 , 60 ]. To bypass the constraints from the underlying robustness polymer substrate and the delamination by wear and tear [ 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 ], LIG was transferred from the substrate by polydimethylsiloxane (PDMS). Notably, the LIG adhered onto the soft and stretchable PDMS film yields flexible, durable, and high-performance electrocardiography monitoring dry electrodes (as shown in Figure 2 h) [ 85 ].…”
Section: Application Of Ligmentioning
confidence: 99%
See 4 more Smart Citations
“…As shown in Figure 2 g, the flexible triboelectric sensing array comprises a touch panel with 9-digital channels based on a LIG-patterned TENG [ 58 , 60 ]. To bypass the constraints from the underlying robustness polymer substrate and the delamination by wear and tear [ 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 ], LIG was transferred from the substrate by polydimethylsiloxane (PDMS). Notably, the LIG adhered onto the soft and stretchable PDMS film yields flexible, durable, and high-performance electrocardiography monitoring dry electrodes (as shown in Figure 2 h) [ 85 ].…”
Section: Application Of Ligmentioning
confidence: 99%
“…Furthermore, the microstructure and the electrical conductivity of the prepared porous graphene films can also be preciously designed by controlling the laser-scanning parameters. At present, various types of LIG-based electronic devices have been successfully proposed to monitor mechanical [ 16 , 18 , 37 , 58 , 78 , 79 , 83 , 84 , 87 , 88 , 89 , 90 , 94 , 95 , 96 ], environmental [ 80 , 81 , 84 , 97 , 98 , 99 , 100 , 101 , 102 ] and biochemical signals [ 19 , 67 , 82 , 85 , 90 , 103 , 104 , 105 , 106 , 107 ].…”
Section: Application Of Ligmentioning
confidence: 99%
See 3 more Smart Citations