2005
DOI: 10.1016/j.talanta.2004.11.010
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric determination of Imatinib (Gleevec) and its main metabolite using square-wave and adsorptive stripping square-wave techniques in urine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(17 citation statements)
references
References 8 publications
0
17
0
Order By: Relevance
“…Furthermore, the present methods cover at least 4 orders of magnitude of SC concentration compared to only half- [5,6] to two- [2,8] decades of concentration obtained by voltammetry, spectrophotometry and HPLC [2][3][4][5][6]8]. On the other hand, the previously described potentiometric methods [18] suffers from narrower linear measurement range (10 )2 -10 )5 M), detection limit (5Â10 )6 M), longer response time (40 s), shorter life span (5 weeks) and significant interference by ions (Na + , K + , Mg 2+ , NH 4 + ) commonly present in high concentrations in biological fluids.…”
Section: Sc-pt Sc-rementioning
confidence: 95%
See 1 more Smart Citation
“…Furthermore, the present methods cover at least 4 orders of magnitude of SC concentration compared to only half- [5,6] to two- [2,8] decades of concentration obtained by voltammetry, spectrophotometry and HPLC [2][3][4][5][6]8]. On the other hand, the previously described potentiometric methods [18] suffers from narrower linear measurement range (10 )2 -10 )5 M), detection limit (5Â10 )6 M), longer response time (40 s), shorter life span (5 weeks) and significant interference by ions (Na + , K + , Mg 2+ , NH 4 + ) commonly present in high concentrations in biological fluids.…”
Section: Sc-pt Sc-rementioning
confidence: 95%
“…These include electrochemical oxidation on carbon electrodes [2], square-wave and adsorptive stripping square-wave voltammetry [3,4], flow injection analysis using UV-detection [5], extractive spectrophotometry based on the formation of ion-pair complexes of SC with bromocresol green and chromoxane cyanine-R dyes [6], liquid chromatography with detection at 230 nm [7], high performance liquid chromatography (HPLC) [8], and gas chromatography/mass spectrometry [9]. Most of these methods, however, utilize expensive instrumentation, suffer from lack of selectivity, involve careful control of the reaction conditions or derivatization reactions, and require time-consuming pretreatment steps which affect their usefulness for routine analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The voltammetry used in the experiment of Hajian and Ensafi had three-electrodes containing hanging mercury drop electrode as a working electrode, a carbon rod as an auxiliary electrode and an Ag/AgCl (3.0 M KCl) reference electrode. This method was proved only on AFs B1 and B2, where both aflatoxins were found to adsorb and undergo irreversible reduction reaction at the working mercury electrode (Rodriguez et al, 2005). Adsorptive Stripping Voltammetry is an electrochemical method which has no or very low dependence on pH.…”
Section: Adsorptive Stripping Voltammetrymentioning
confidence: 99%
“…Berzas et al proposed the CE for the quantitative determination of FLX and NFLX by MEKC using as surfactant the compound 1-decanesulfonic acid sodium salt [27] and non-aqueous CE [28] was also used for its determination in urine sample. With respect to the analysis of saliva no determination by CE was found until now.…”
Section: Introductionmentioning
confidence: 99%