2019 IEEE East-West Design &Amp; Test Symposium (EWDTS) 2019
DOI: 10.1109/ewdts.2019.8884473
|View full text |Cite
|
Sign up to set email alerts
|

Voltage Regulation Analysis in Energy Transmission Systems Using STATCOM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Else, it absorbs reactive power (inductive) from the system. A key advantage of the STATCOM over the SVC is that it provides full reactive power compensation regardless of the system voltage.The STATCOM has been extensively researched on for voltage [13] and rotor angle [14] stability improvement. In a comparative study of the SVC and STATCOM, the latter performed better in improvement of the system voltage profiles [15] and on transient stability improvement [16].…”
Section: Literature Reviewmentioning
confidence: 99%
See 1 more Smart Citation
“…Else, it absorbs reactive power (inductive) from the system. A key advantage of the STATCOM over the SVC is that it provides full reactive power compensation regardless of the system voltage.The STATCOM has been extensively researched on for voltage [13] and rotor angle [14] stability improvement. In a comparative study of the SVC and STATCOM, the latter performed better in improvement of the system voltage profiles [15] and on transient stability improvement [16].…”
Section: Literature Reviewmentioning
confidence: 99%
“…where 𝑃 𝑜 (𝛿) = Real power transmission of the line before compensation at a given angle δ 𝑄 𝑜 (𝛿)= Reactive power transmission of the line before compensation at a given angle δ The superior ability of the UPFC allows for power control for any transmission angle δ as in ( 13) and (14). Past research work has shown the UPFC to tremendously improve the voltage [28] and rotor angle stability [29], [30].…”
Section: Literature Reviewmentioning
confidence: 99%
“…The FACTS controllers of a STATCOM have a very fast response and flexible operation at dynamic circumstances with prescribed capacity ranges. Therefore, the DC capacitor voltages remain ripple-free for the system [34][35][36]. The submodule capacitor of three-phase multi modular converter sequences is being investigated to improve the system voltage imbalances and to limit the compensation current under dynamic grid conditions [37].…”
Section: Introductionmentioning
confidence: 99%