Vibroplasty for Mixed and Conductive Hearing Loss

Abstract: Modern application methods of an active middle ear implant (VSB) open new therapeutic options for patients with various outer and middle ear diseases resulting in conductive or mixed hearing loss. Titanium couplers can help to couple the active middle ear implant in a standardized way to remnants of the ossicular chain or to the round window. Thus, the active middle ear implant has been established as an alternative treatment option for patients with mixed and conductive hearing. However, the heterogeneity of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
31
0
1

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 55 publications
(34 citation statements)
references
References 44 publications
2
31
0
1
Order By: Relevance
“…Audiometric candidacy criteria include bone conduction thresholds up to 65 dB HL at 500 Hz and 85 dB HL at 6,000 Hz [29]. Uses for both children and mixed hearing loss have also been investigated [29,30,33]. Like the Otologics MET and Carina, flexibility of the internal component placement has the potential to make this device appropriate for patients with a wide range of middle ear anomalies.…”
Section: Clinical Indicationsmentioning
confidence: 99%
See 3 more Smart Citations
“…Audiometric candidacy criteria include bone conduction thresholds up to 65 dB HL at 500 Hz and 85 dB HL at 6,000 Hz [29]. Uses for both children and mixed hearing loss have also been investigated [29,30,33]. Like the Otologics MET and Carina, flexibility of the internal component placement has the potential to make this device appropriate for patients with a wide range of middle ear anomalies.…”
Section: Clinical Indicationsmentioning
confidence: 99%
“…The audio processor contains a microphone, speech-processing capabilities, transmitting coil, magnet, and battery [29,35]. The internal VORP is comprised of a receiver module, magnet, conductor link, and floating mass transducer (FMT).…”
Section: System Componentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Numerous reports have been published on active middle ear implants (AMEI) in case of moderate MHL [Baumgartner et al, 2010;Beltrame et al, 2009;Bernardeschi et al, 2011;Colletti et al, 2013;Dumon et al, 2009;Martin et al, 2009;Schwab et al, 2012]. Luers et al [2013] provided a recent overview of new coupling methods for an AMEI to the stapes structure and round window in case of conductive hearing loss or MHL. For severe MHL the outcome with AMEI remains variable [Verhaegen et al, 2012].…”
Section: Introductionmentioning
confidence: 99%