2015
DOI: 10.1016/j.jcin.2015.04.017
|View full text |Cite
|
Sign up to set email alerts
|

Very Late Thrombosis of a Transcatheter Aortic Valve-in-Valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 2 publications
1
6
0
Order By: Relevance
“…Surgical explantation of older TAVR valve cases are increasingly reported recently, being exclusively after 2015. 4,10,[15][16][17] The description of the valve or the aortic finding in these reports is in line with our observations. Aortic endarterectomy is seemingly mandatory with respect to valves older than a year after implantation and unplanned aortic replacement appears frequently necessary in these old valve cases.…”
Section: Discussionsupporting
confidence: 87%
See 1 more Smart Citation
“…Surgical explantation of older TAVR valve cases are increasingly reported recently, being exclusively after 2015. 4,10,[15][16][17] The description of the valve or the aortic finding in these reports is in line with our observations. Aortic endarterectomy is seemingly mandatory with respect to valves older than a year after implantation and unplanned aortic replacement appears frequently necessary in these old valve cases.…”
Section: Discussionsupporting
confidence: 87%
“…As for previous TAVR valve explant and recommended surgical technique in the literature, we have identified 11 case reports that involved description of valve explant technique from 2008 to 2019. 4,10,[15][16][17][18][19][20][21][22][23] The time interval between TAVR implant and explant was from immediate to 7 years (median 187 days; IQR, 21-913 days). Surgical explantation of older TAVR valve cases are increasingly reported recently, being exclusively after 2015.…”
Section: Discussionmentioning
confidence: 99%
“…A recent clinical study has suggested that the frequency of post-TAVR thrombus formation may be as high as 40% [6]. In addition, valve thrombosis has been increasingly observed in patients undergoing valve-in-valve (ViV) procedures [7][8][9][10]. The thrombotic materials after TAVR and ViV procedures are predominantly found on the aortic side of the leaflets (Figs 1a, 1b) [6,7,11].…”
mentioning
confidence: 99%
“…(a) Thrombotic material adhered to the three leaflets of the Sapien XT after valve-in-valve in the CoreValve. (Reprinted from[8] with permission from Elsevier.) (b) Note the greater presence of a redbrown post-transcatheter aortic valve replacement thrombus (red arrow) on the aortic surface of the right coronary cusp (RCC) of the CoreValve.…”
mentioning
confidence: 99%
“…Autopsy findings have also shown the presence of thrombus on the right and noncoronary leaflets of a CoreValve implanted within another CoreValve THV . Marti et al reported thrombotic material on all three leaflets of a SAPIEN XT implanted within a CoreValve THV. Furthermore, thrombus formation has also been observed on a SAPIEN XT in a Hancock II bioprosthesis following transcatheter mitral ViV implantation …”
Section: Leaflet Thrombosis In Transcatheter Valve‐in‐valvementioning
confidence: 99%