Verification of treatment planning algorithms using optically stimulated luminescent dosimeters in a breast phantom

Abstract: Aim:The aim of this study is to measure and compare the surface dose of treated breast and contralateral breast with the treatment planning system (TPS) calculated dose using calibrated optically stimulated luminescent dosimeter (OSLD) in an indigenous wax breast phantom.Materials and Methods:Three-dimensional conformal plans were generated in eclipse TPS v. 13 to treat the left breast of a wax phantom for a prescribed dose of 200 cGy. The plans were calculated using anisotropic analytical algorithm (AAA) and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…During the planning of whole breast radiotherapy, even if a wedge plan is the choice, a plan with an enhanced dynamic wedge (EDW) ought to be used as the dose to the peripheral regions is greatly reduced with the use of an EDW as reported by our study. 15…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…During the planning of whole breast radiotherapy, even if a wedge plan is the choice, a plan with an enhanced dynamic wedge (EDW) ought to be used as the dose to the peripheral regions is greatly reduced with the use of an EDW as reported by our study. 15…”
Section: Discussionmentioning
confidence: 99%
“…14 The procedure adopted for the calibration of nanoDot OSLDs used in our study is discussed elsewhere. 15 The 'hardware' mode and 'high dose' setting in the reader were selected for the readout of exposed OSLDs. The calibration factors (cGy/counts) were obtained as the ratio of reference dose delivered to the OSLDs to the net counts from the corresponding OSLDs.…”
Section: Methodsmentioning
confidence: 99%
“…Dynamic wedge filters and/or the field in field technique were used to obtain a homogeneous dose distribution. 6,7 In 3DCRT, 42.4 Gy in 16 fractions of 2.65 Gy was prescribed to the isocenter. A VMAT plan used dual partial arcs of 40° to 50° with a collimator angle of 30° and treatment couch angle of 0°, rotating in opposite directions.…”
Section: Methodsmentioning