2015
DOI: 10.1111/jsm.12958
|View full text |Cite
|
Sign up to set email alerts
|

Variation in Penile Hemodynamics by Anatomic Location of Cavernosal Artery Imaging in Penile Duplex Doppler Ultrasound

Abstract: Introduction Standard operating procedures (SOP) for penile duplex Doppler ultrasound (PDDU) were published in 2013 to promote uniform vascular assessment for erectile dysfunction (ED). However, SOPs do not specify a standard anatomic location for cavernosal artery (CA) imaging. Aim The aim of this study was to determine the effects of CA imaging location on measured penile hemodynamics assessed by PDDU. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 19 publications
(29 reference statements)
0
13
0
1
Order By: Relevance
“…Possible explanations might be multiple. As described by Pagano and Stahl (), the location of cavernous artery imaging appears to have a significant effect on the resulting measurement with more proximal measurements being significantly higher than those taken more distally. P‐DCU performed using alprostadil (PGE 1 ) probes the adenylated cyclase – cAMP pathway to induce erection and this is somehow independent from the endothelium mediated NO production.…”
Section: Discussionmentioning
confidence: 82%
“…Possible explanations might be multiple. As described by Pagano and Stahl (), the location of cavernous artery imaging appears to have a significant effect on the resulting measurement with more proximal measurements being significantly higher than those taken more distally. P‐DCU performed using alprostadil (PGE 1 ) probes the adenylated cyclase – cAMP pathway to induce erection and this is somehow independent from the endothelium mediated NO production.…”
Section: Discussionmentioning
confidence: 82%
“…About 5 to 10 minutes after injection, the sampling gate (size, 0.5 mm) was placed at approximately l to 2 cm from the origins of the bilateral cavernous arteries and their diameters measured, and the average was recorded . The spectrums of cavernosal arteries were observed repeatedly at the same sampling locations as mentioned above, respectively, taking care to keep the angle between the sampling line and the longitudinal axis of the blood vessel less than 60 degrees .…”
Section: Methodsmentioning
confidence: 99%
“…Although there is no generalised agreement on the interpretation of its results (Lee et al, 1993;Lue et al, 1985;Sikka, Hellstrom, Brock, & Morales, 2013) and there is also a known intra-and interobserver variation in its results (Pagano & Stahl, 2015), an effort has been made to develop standardised protocols for penile vascular assessment in ED (Sikka et al, 2013). The protocols aim to establish uniformity on examination and reporting, thus allowing better data interpretation and comparison.…”
Section: Introductionmentioning
confidence: 99%