2016
DOI: 10.1016/j.enbuild.2016.03.054
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a lumped RC model for thermal simulation of a double skin natural and mechanical ventilated test cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(22 citation statements)
references
References 33 publications
0
19
0
Order By: Relevance
“…In this regard, computer-based analyses are well recognized to support the understanding of complex systems (such as NZEBs) by providing feedbacks on the performance of all the investigated innovative design scenarios [12]. Based on high order RC networks, several new dynamic simulation models have been developed for analyzing, as an example, the impact on the building energy demand of glazed/opaque surfaces and internal solar radiation [50], the thermal behavior of multi glazing façades [51], the thermo-physical behavior of a Phase Change Material (PCM) layer in combination with transparent and opaque materials [52], the performance of Building Integrated Solar Thermal and Photovoltaic systems (BIST-BIPVT) [53]. New BEPS computer-based models are also required to be flexible and suitable for the calculation of household actions and to effectively account model occupants' behavior [54].…”
Section: Innovative Capabilities Of Detectmentioning
confidence: 99%
“…In this regard, computer-based analyses are well recognized to support the understanding of complex systems (such as NZEBs) by providing feedbacks on the performance of all the investigated innovative design scenarios [12]. Based on high order RC networks, several new dynamic simulation models have been developed for analyzing, as an example, the impact on the building energy demand of glazed/opaque surfaces and internal solar radiation [50], the thermal behavior of multi glazing façades [51], the thermo-physical behavior of a Phase Change Material (PCM) layer in combination with transparent and opaque materials [52], the performance of Building Integrated Solar Thermal and Photovoltaic systems (BIST-BIPVT) [53]. New BEPS computer-based models are also required to be flexible and suitable for the calculation of household actions and to effectively account model occupants' behavior [54].…”
Section: Innovative Capabilities Of Detectmentioning
confidence: 99%
“…The shape and variability of presented waveforms is the same. Maximum and minimum hourly values of thermal power differed from 116 W (7-th hour) to 1466 W (11) and from 45 W (17) to 223 W (12) in the case 600 and 900, respectively. Lower discrepancies between individual methods occurred for the heavy building case.…”
Section: Bestest Testsmentioning
confidence: 93%
“…Because of its simplicity and low computational demand the lumped capacitance method was commonly applied in researches [8][9][10][11][12][13] and standards, as VDI 6007 [14][15] or PN-EN ISO 13790 [16]. It is based on the thermal-electrical analogy [17][18].…”
Section: Introductionmentioning
confidence: 99%
“…Further, high energy consumption is related to the poor insulation of building skins, especially that of windows. Various studies have been conducted to investigate potential approaches for improving the thermal performance of windows, including the use of double skins [6][7][8][9][10][11][12][13][14][15], phase change materials (PCM) [16][17][18][19][20][21][22], window blinds [23][24][25][26][27][28][29][30][31][32], awnings [33][34][35], and light shelves [36][37][38][39][40][41]. Although several of these apparatuses may be efficiently used to reduce the energy consumption of the buildings, they often have high installation costs or are difficult to be 2 of 14 applied to the existing buildings.…”
Section: Introductionmentioning
confidence: 99%