2013
DOI: 10.1016/j.scispo.2012.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Validation de la mesure segmentaire de la composition corporelle en comparaison avec la DEXA : intérêt de la mesure de la masse grasse tronculaire

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…This device measures total resistance of the body to an alternative electric current of 50 kHz [17][18]. Body fat mass, fat-free mass were calculated in each segment of the body according to manufacturer's database-derived disclosed equations, and total water with published equations using the classical cylindric model and Hanai's mixture theory [19].…”
Section: Bioelectrical Impedance Measurementsmentioning
confidence: 99%
“…This device measures total resistance of the body to an alternative electric current of 50 kHz [17][18]. Body fat mass, fat-free mass were calculated in each segment of the body according to manufacturer's database-derived disclosed equations, and total water with published equations using the classical cylindric model and Hanai's mixture theory [19].…”
Section: Bioelectrical Impedance Measurementsmentioning
confidence: 99%
“…Prior to the exercise-test, subjects' body composition was assessed with bioimpedance analysis with a six terminal impedance plethismograph BIACORPUS RX 4000 Biacorpus RX4000, (SoAGIL DEVELOPPEMENT, 8 avenue Jean-Jaurès F-92130 Issy-les-Moulineaux, France) with data analysis with the software BodyComp 8.4. This device measures total resistance of the body to an alternative electric current of 50 kHz [20,21]. Body fat mass and fat-free mass were calculated in each segment of the body according to manufacturer's database-derived disclosed equations, and total water with published equations using the classical cylindric model and Hanai's mixture theory [22].…”
Section: Bioelectrical Impedance Measurementsmentioning
confidence: 99%
“…Body composition, i.e., the measurement of fat mass and Fat Free Mass (FFM), was assessed with bioimpedance analysis with a six-terminal impedance plethysmograph BIACORPUS RX4000 BiacorpusRX4000, (Healthnesslink,79 8 avenue Jean-Jaurès 92130 Issy-les-Moulineaux, France) with data analysis with the software BodyComp8.4. This device measures total resistance of the body to an alternative electric current of 50kHz [27,28]. Body fat mass, fat-free mass was calculated in each segment of the body according to manufacturer's database-derived disclosed equations, and total water with published equations using the classical cylindric model and Hanai's mixture theory [29].…”
Section: Measurementsmentioning
confidence: 99%