2021
DOI: 10.3906/sag-1912-132
|View full text |Cite
|
Sign up to set email alerts
|

Utility of the Pleth Variability Index in predicting anesthesia-induced hypotension in geriatric patients

Abstract: The utility of the pleth variability index in predicting anesthesia-induced hypotension in geriatric patients Abstract Background/aim: Anesthesia induced hypotension may have negative consequences in geriatric patients. Therefore, predicting hypotension remains an important topic for anesthesiologists. Pleth Variability Index (PVI) measurement provides information about the fluid status and vascular tonus of the patients. In our study, the ability of Pleth Variability Index to predict hypotension after general… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(13 citation statements)
references
References 16 publications
0
13
0
Order By: Relevance
“…[13][14][15][16] ORi is a parameter-driven from this device that is between 0 and 1 values, and it is sensitive to the changes in arterial oxygenation in the blood, with the range of 100 to 200 mmHg. [2,[8][9][10]13,[18][19][20][21] When oxygenation is in the moderate hyperoxic content showing an arterial blood oxygenation value of 100-240 mmHg in arterial blood gas analysis, the pulse oximeter SpO2 value remains 100%, whereas there is a decrease in the value of ORi. [2,[18][19][20][21] In our study, Figure 1 and Table 4 provides data on timedependent correlations between ORi with SpO2.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…[13][14][15][16] ORi is a parameter-driven from this device that is between 0 and 1 values, and it is sensitive to the changes in arterial oxygenation in the blood, with the range of 100 to 200 mmHg. [2,[8][9][10]13,[18][19][20][21] When oxygenation is in the moderate hyperoxic content showing an arterial blood oxygenation value of 100-240 mmHg in arterial blood gas analysis, the pulse oximeter SpO2 value remains 100%, whereas there is a decrease in the value of ORi. [2,[18][19][20][21] In our study, Figure 1 and Table 4 provides data on timedependent correlations between ORi with SpO2.…”
Section: Discussionmentioning
confidence: 99%
“…This study shows that ORi has a signi cant correlation with PaO2 (r = 0.671, p < 0.01). [18] In other studies, a continuous correlation between ORi and PaO2 values was demonstrated [13][14][15][19][20][21]…”
mentioning
confidence: 90%
See 3 more Smart Citations