2014
DOI: 10.3341/kjo.2014.28.2.164
|Get access via publisher |Summarize |Cite
|
Sign up to set email alerts

Using ImageJ to Evaluate Optic Disc Pallor in Traumatic Optic Neuropathy

Abstract: PurposeTo evaluate optic disc pallor using ImageJ in traumatic optic neuropathy (TON).MethodsThis study examined unilateral TON patients. The optic disc was divided into 4 quadrants (temporal, superior, nasal, and inferior), consistent with the quadrants on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness maps. Optic disc photography was performed and disc pallor was quantified using gray scale photographic images imported into ImageJ software. The correlation between optic disc pa… Show more

Search citation statements

Order By: Relevance

Paper Sections

Select...
6
2
1
0

Citation Types

0
7
0
0

Year Published

Range
2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations

Cited by 7 publications

(7 citation statements)
references

References 14 publications

0
7
0
0
Order By: Relevance
How this paper cites the one you are viewing
“…Unfortunately, these studies all required a special filter while taking fundus photographs to obtain an ideal image for assessing optic disc colour, which is not the usual case in clinical practice. Quantitative measurement of optic disc pallor without using a special filter also have been reported (Kang & Kim ; Nakano et al. ).…”
Section: Discussion
mentioning
confidence: 89%
“…Unfortunately, these studies all required a special filter while taking fundus photographs to obtain an ideal image for assessing optic disc colour, which is not the usual case in clinical practice. Quantitative measurement of optic disc pallor without using a special filter also have been reported (Kang & Kim 2014;Nakano et al 2016). However, these studies were not fully automated and were based on colour discrimination of red, green and blue pixels using image analysis software, which employed calculation algorithms using the mean intensity of each colour to quantify optic disc pallor (Nakano et al 2016).…”
Section: Discussion
mentioning
confidence: 93%
“…First, our CAD system detected optic disc pallor through a fully automated process. Second, the combination of corrected green channel images and blue channel images provided a high contrast of the optic disc compared to previous studies (Schwartz et al 1973;Hendrickson et al 1984;Miller & Caprioli 1988;O'Brien 1991;Sagaties Farmer et al 1997;Vilser et al 2008;Kang & Kim 2014;Nakano et al 2016). Third, we adopted two novel parameters to overcome the major obstacles of objective assessment of optic disc pallor in previous studies (Schwartz et al 1973;Hendrickson et al 1984;Miller & Caprioli 1988;O'Brien 1991;Sagaties Farmer et al 1997;Vilser et al 2008;Kang & Kim 2014;Nakano et al 2016).…”
Section: Discussion
mentioning
confidence: 99%
“…There have been previous attempts to measure optic disc pallor on fundus photographs (Schwartz et al 1973;Sorensen 1979;Zenker et al 1983;Hendrickson et al 1984;Miller & Caprioli 1988;O'Brien 1991;Sagaties Farmer et al 1997;Vilser et al 2008;Kang & Kim 2014;Nakano et al 2016). Unfortunately, these studies all required a special filter while taking fundus photographs to obtain an ideal image for assessing optic disc colour, which is not the usual case in clinical practice.…”
Section: Discussion
mentioning
confidence: 99%
See 3 more Smart Citations