2000
DOI: 10.1016/s0168-9002(00)00333-8
|View full text |Cite
|
Sign up to set email alerts
|

Using direct illumination CCDs as high-resolution area detectors for X-ray scattering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
51
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(51 citation statements)
references
References 7 publications
0
51
0
Order By: Relevance
“…For each frame, the CCD was transformed in a photon-counting detector, as described in Livet et al (2000). Intensities correspond to counts, and the log units show the large dynamics obtained (unpublished results obtained at the ID20 beamline of ESRF).…”
Section: Figurementioning
confidence: 99%
“…For each frame, the CCD was transformed in a photon-counting detector, as described in Livet et al (2000). Intensities correspond to counts, and the log units show the large dynamics obtained (unpublished results obtained at the ID20 beamline of ESRF).…”
Section: Figurementioning
confidence: 99%
“…In our experiment, the CCD was divided into 18 strips of 64 rows and the irradiated region was limited by means of slits. For each frame, the measured intensity was analysed with the 'droplet algorithm' (DA), which, for low counting rates, transforms the direct-illumination CCD in a photoncounting area detector (Livet et al, 2000). The elementary kinetic shift times t were 25, 150, 350 and 1000 ms. Fig.…”
Section: Homodyne and Heterodyne Correlations In A Latex Suspensionmentioning
confidence: 99%
“…For practical experiments, ' 10 mrad, primarily because the CCD detectors used (Livet et al, 2000) have a 20 mm resolution with a sample-to-detector distance of the order of 2 m. This means that ' 10 mm, and that the irradiated surface is at least two orders of magnitude smaller than in light scattering (obviously, a laser beam can be focused to a size smaller than 10 mm, but its divergence due to diffraction gives an effective beam size of about 100 mm for a sample of a thickness in the millimetre range). This size can be further reduced with the new X-ray focusing elements (Schroer et al, 2003;Di Fabrizio et al, 1999).…”
Section: Introductionmentioning
confidence: 99%
“…In order to improve statistics, the use of an area detector is indispensable. A droplet algorithm [33] is used to identify the photon events and all points lying within the area of the detector are treated as equivalent in the reciprocal space and all are used to calculate an ensemble average. This is reasonable because for high X-ray energies the Ewald sphere is flat for the solid angle occupied by the area detector and also gradients of the inverse correlation time in the diffusion models are rather flat as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%