1997
DOI: 10.1016/s0378-4347(97)00469-6
|View full text |Cite
|
Sign up to set email alerts
|

Use of ion trap gas chromatography–tandem mass spectrometry for detection and confirmation of anabolic substances at trace levels in doping analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
9
0
1

Year Published

2000
2000
2012
2012

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(11 citation statements)
references
References 4 publications
1
9
0
1
Order By: Relevance
“…For screening and confirmation of anabolic steroids, gas chromatography coupled to mass spectrometry (GC-MS) is the technique commonly used for the analysis of urine samples by anti-doping or analytical laboratories [2][3][4][5]. Improved analytical sensitivity, leading to increased periods of detection post drug administration, can be achieved in urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) [6][7][8][9] or liquid chromatography-tandem mass spectrometry (LC-MS/MS) [10][11][12][13][14][15]. Efficient control of the illegal use of anabolic steroids must both take into account metabolic patterns and associated kinetics of elimination [5,8,16].…”
Section: Introductionmentioning
confidence: 99%
“…For screening and confirmation of anabolic steroids, gas chromatography coupled to mass spectrometry (GC-MS) is the technique commonly used for the analysis of urine samples by anti-doping or analytical laboratories [2][3][4][5]. Improved analytical sensitivity, leading to increased periods of detection post drug administration, can be achieved in urine using gas chromatography-tandem mass spectrometry (GC-MS/MS) [6][7][8][9] or liquid chromatography-tandem mass spectrometry (LC-MS/MS) [10][11][12][13][14][15]. Efficient control of the illegal use of anabolic steroids must both take into account metabolic patterns and associated kinetics of elimination [5,8,16].…”
Section: Introductionmentioning
confidence: 99%
“…Because of the high sensitivity of the m/z = 405 signal, this ion was chosen for quantification and for MS-MS analysis. The collision-induced dissociation (CID) process for this analysis was by non-resonant excitation chosen because more structural information can be obtained (Muñoz-Guerra et al, 1997). Optimal CID conditions were evaluated using the automatic method development (AMD) feature that allowed different parameters to be applied during each successive scan.…”
Section: Methodsmentioning
confidence: 99%
“…L'utilisation d'une CPG-SM-SM à trappe d'ions a permis de détecter les traces de 23 stéroïdes (27). Cette technique très sensible permet de détecter et de confirmer des cas positifs qui n'auraient pu l'être par des méthodes de CPG-SM de routine.…”
Section: Analyses Réalisées Pour Les Humainsunclassified