Use of handheld reflectance confocal microscopy for in vivo diagnosis of solitary facial papules: a case series

Abstract: For clinically and dermoscopically equivocal small papules on curved facial surfaces, handheld RCM may be particularly helpful in differentiating benign lesions from skin cancer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
18
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
4

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 19 publications
(43 reference statements)
1
18
0
Order By: Relevance
“…Handheld reflectance confocal microscopy imaging was performed with commercially‐available in vivo RCM system (Vivascope3000; CaliberID) as previously described . In brief, the HH‐RCM uses 830 nm laser and is characterized by horizontal resolution of 1.25 μm, vertical resolution of 5 μm, and maximal imaging depth of about 250 μm which corresponds to the superficial reticular dermis.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Handheld reflectance confocal microscopy imaging was performed with commercially‐available in vivo RCM system (Vivascope3000; CaliberID) as previously described . In brief, the HH‐RCM uses 830 nm laser and is characterized by horizontal resolution of 1.25 μm, vertical resolution of 5 μm, and maximal imaging depth of about 250 μm which corresponds to the superficial reticular dermis.…”
Section: Methodsmentioning
confidence: 99%
“…However, the TWP‐RCM is bulky and provides limited access to curved surfaces, such as the nose, ear and peri‐orbital regions where BCC frequently arises. Recently, a handheld‐RCM probe (HH‐RCM, Vivascope 3000; CaliberID) has been introduced to clinical practice . The HH‐RCM has a smaller probe and is more accessible for application to the curved facial surfaces.…”
Section: Introductionmentioning
confidence: 99%
“…Because of its narrow probe, however, the handheld RCM has a field of view limited to 1 3 1 mm. 2 In its current form, the dimensions of the wide-probe RCM imaging station are 30 3 23 3 54 in (76.2 3 58. 4 3 137.2 cm); this device can be stowed at the corner of a standard examination room and can be mobilized between examination rooms.…”
Section: Fundamentals Of Reflectance Confocal Microscopymentioning
confidence: 99%
“…However, though CLSM provides crucial information when evaluating equivocal reactions, the technology is expensive and time consuming. A newly available complimentary commercial product, a handheld CLSM device [25], might shorten the time required for data acquisition; however, it does not alter financial cost. Further studies are required to evaluate its cost-effectiveness in daily patch test practice.…”