2000
DOI: 10.1016/s0360-3016(00)00809-9
|View full text |Cite
|
Sign up to set email alerts
|

Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
92
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 188 publications
(93 citation statements)
references
References 17 publications
1
92
0
Order By: Relevance
“…Our method using fiducial markers and two sets of fluoroscopy was also shown to be useful to reduce set-up error compared to the skin-based setting (5,13,15). In this study, we focused on intra-fraction displacement according to treatment time, from the beginning of each treatment session after the daily set-up procedure was finished.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Our method using fiducial markers and two sets of fluoroscopy was also shown to be useful to reduce set-up error compared to the skin-based setting (5,13,15). In this study, we focused on intra-fraction displacement according to treatment time, from the beginning of each treatment session after the daily set-up procedure was finished.…”
Section: Discussionmentioning
confidence: 99%
“…The usefulness of fiducial markers such as radio-opaque materials or electromagnetic devices for the assessment of inter-fraction prostate displacement has also been well established (5)(6)(7)(8). Precise re-positioning using an IGRT technique with prostate markers has shown to be useful for reducing the margin of the planning target volume (5)(6)(7)(8).…”
Section: Introductionmentioning
confidence: 99%
“…If the EPID images are acquired using respiration gating, the set-up margin can be substantially reduced, especially if the GTV can be seen on the images, which is a possibility with the ever-increasing improvement in EPID hardware and software. Furthermore, gating can be based on internal markers embedded in the tumour rather than an external respiration signal, 13,16,17,30 and thus the positional uncertainties can be substantially reduced.…”
Section: Introductionmentioning
confidence: 99%
“…These results suggested that using the ExacTrac X‐ray 6D system can increase the localization accuracy for patients and may reduce the internal margin. Another study (14) investigated the difference in the marker position between manual setup using skin markers and setup using a fluoroscopic X‐ray system for the prostate. It reported that dislocation was decreased by less than 1 mm for the lateral, anteroposterior, and craniocaudal directions using the RTRT system.…”
Section: Introductionmentioning
confidence: 99%