UPFC for Enhancing Power System Reliability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
49
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(49 citation statements)
references
References 13 publications
0
49
0
Order By: Relevance
“…From the fig 2.4 once the series CMI inject voltage is decided by (5), the new sending-end voltage and the transmission line current will be determined consequently [10].…”
Section: Doi: 1018535/ijecs/v6i333mentioning
confidence: 99%
“…From the fig 2.4 once the series CMI inject voltage is decided by (5), the new sending-end voltage and the transmission line current will be determined consequently [10].…”
Section: Doi: 1018535/ijecs/v6i333mentioning
confidence: 99%
“…The pulse width modulation (PWM) technique is used to provide a high-quality output voltage, to reduce the size of the required filter, and to achieve a fast dynamic response [1]. The harmonics generated by the inverter are attenuated by a second order filter, providing a low THD voltage to the transformer [3]. The Unified Power Flow Controller (UPFC) was proposed' for real turn-off time control and dynamic compensation of ac transmission systems, providing the necessary functional flexibility required to solve many of the problems facing the utility industry.…”
Section: Unified Power Flow Controller (Upfc)mentioning
confidence: 99%
“… Dynamic and transient stability improvement by appropriate modulation of the controller references. While the application of UPFC for load flow control and in stability improvement has been discussed in [3,4], a detailed discussion on control strategy for UPFC in which we control real power flow through the line, while regulating magnitudes of the voltages at its two ports.…”
Section: Unified Power Flow Controller (Upfc)mentioning
confidence: 99%
“…The real power can be exchanged by the SSSC with the line flows bi-directionally to the line through the STATCOM and the common dc link capacitor. The UPFC has been used widely to improve damping and dynamic performance of the system [20,21] and also enhancing reliability of power system [22]. To incorporate synchronous AC grid, UPFC is also used in the system [23] First rotor angle deviation and speed deviation are analyzed with and without FACT devices in a SingleMachine Infinite Bus (SMIB) power system, and then PID controller is incorporated with feedback signal [24] but it is usually introduced before the plant.…”
Section: Introductionmentioning