2011
DOI: 10.1016/j.micron.2010.12.002
|View full text |Cite
|
Sign up to set email alerts
|

Understanding the micro structure of Berea Sandstone by the simultaneous use of micro-computed tomography (micro-CT) and focused ion beam-scanning electron microscopy (FIB-SEM)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
59
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 135 publications
(68 citation statements)
references
References 19 publications
0
59
0
Order By: Relevance
“…SRXTM methods may be complemented with nanoscale approaches such as focused-ion-beam scanning electron microscopy (Keller et al, 2011;Bera et al, 2011), transmission electron microscopy (Kanitpanyacharoen et al, 2011) and X-ray nanotomography (Nelson et al, 2011;Grew et al, 2010). Overall, this round-robin experiment of SRXTM documented that all three beamlines produce similar results with microstructural resolution of approximately 2 mm.…”
Section: Discussionmentioning
confidence: 77%
“…SRXTM methods may be complemented with nanoscale approaches such as focused-ion-beam scanning electron microscopy (Keller et al, 2011;Bera et al, 2011), transmission electron microscopy (Kanitpanyacharoen et al, 2011) and X-ray nanotomography (Nelson et al, 2011;Grew et al, 2010). Overall, this round-robin experiment of SRXTM documented that all three beamlines produce similar results with microstructural resolution of approximately 2 mm.…”
Section: Discussionmentioning
confidence: 77%
“…In the field of reservoir characterization, micro-CT has become an interesting research technique, not only for the quantification of the 3D heterogeneity of reservoir properties (Bera et al, 2010;Remeysen and Swennen, 2008) but also for the sedimentary and diagenetic phases (Grochau et al, 2010;Nakashima et al, 2008). Lesher et al (2009) combined highpressure set-ups and synchrotron radiation to model the Earth's thermal state, the chemical differentiation, and the dynamic processes, since it required knowledge of properties of silicate and metallic melts at high pressure.…”
Section:  3d Grain Analysismentioning
confidence: 99%
“…However, this method produces 2D pore structures that are not representative of 3D pore space. Micro-computed tomography (micro-CT) [28,29] or focused ion beam-scanning electron microscopy (FIB-SEM) [30] can be used to reconstruct the 3D pore structure for incorporation into porous media micromodels. Reproducing 3D pore space using these approaches is expensive and limited in scale [31][32][33], which led to a recent proposal to utilize microfluidic devices with patterned channels as a 2.5D structure to mimic the transport characteristics of 3D pore space [34].…”
Section: Introductionmentioning
confidence: 99%