Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Friction between archwires and labial brackets has received considerable attention; however, information on the frictional behaviour of commercially available lingual brackets is limited. The aim of this study was to investigate the frictional resistance resulting from a combination of lingual orthodontic brackets (7th Generation, STb, Magic, and In-Ovation L) and stainless steel archwires at 0, 5, and 10 degrees of second-order angulation. Each bracket type (n = 30) was tested with three different sizes of archwires. Static and kinetic frictional forces were evaluated with a universal testing machine. Statistical analysis of the data was performed with non-parametric Kruskal-Wallis and Dunn's multiple comparison tests. All tested brackets showed higher frictional forces as the wire size and second-order angulation increased. The lowest friction was found with In-Ovation L brackets and 0.016 inch archwires at 0 degrees angulation, and the greatest friction with a combination of STb brackets and 0.017 × 0.025 inch archwires at 10 degrees angulation. For all combinations, Magic and In-Ovation L brackets showed lower frictional resistance when compared with 7th Generation and STb brackets. The slot width (occluso-gingival dimension) of the brackets, measured using the optics of a microhardness machine, showed that all brackets were oversized and that Magic brackets had the largest slot width. Surface roughness of the brackets investigated using atomic force microscopy and scanning electron microscopy, demonstrated that the 7th Generation brackets had the greatest surface roughness.
Friction between archwires and labial brackets has received considerable attention; however, information on the frictional behaviour of commercially available lingual brackets is limited. The aim of this study was to investigate the frictional resistance resulting from a combination of lingual orthodontic brackets (7th Generation, STb, Magic, and In-Ovation L) and stainless steel archwires at 0, 5, and 10 degrees of second-order angulation. Each bracket type (n = 30) was tested with three different sizes of archwires. Static and kinetic frictional forces were evaluated with a universal testing machine. Statistical analysis of the data was performed with non-parametric Kruskal-Wallis and Dunn's multiple comparison tests. All tested brackets showed higher frictional forces as the wire size and second-order angulation increased. The lowest friction was found with In-Ovation L brackets and 0.016 inch archwires at 0 degrees angulation, and the greatest friction with a combination of STb brackets and 0.017 × 0.025 inch archwires at 10 degrees angulation. For all combinations, Magic and In-Ovation L brackets showed lower frictional resistance when compared with 7th Generation and STb brackets. The slot width (occluso-gingival dimension) of the brackets, measured using the optics of a microhardness machine, showed that all brackets were oversized and that Magic brackets had the largest slot width. Surface roughness of the brackets investigated using atomic force microscopy and scanning electron microscopy, demonstrated that the 7th Generation brackets had the greatest surface roughness.
Objective The aim was to investigate the effect of mechanical vibration on root resorption with or without orthodontic force application. Material and methods Twenty patients who required maxillary premolar extractions as part of orthodontic treatment were randomly divided into two groups of 10: no-force group and force group. Using a split-mouth procedure, each patient’s maxillary first premolar teeth were randomly assigned as either vibration or control side for both groups. A buccally directed vibration of 50 Hz, with an Oral-B HummingBird device, was applied to the maxillary first premolar for 10 min/day for 12 weeks. After the force application period, the maxillary first premolars were extracted and scanned with micro-computed tomography. Fiji (ImageJ), performing slice-by-slice quantitative volumetric measurements, was used for resorption crater calculation. Total crater volumes were compared with the Wilcoxon and Mann–Whitney U tests. Results The total crater volumes in the force and no-force groups were 0.476 mm3 and 0.017 mm3 on the vibration side and 0.462 mm3 and 0.031 mm3 on the control side, respectively. There was no statistical difference between the vibration and control sides (P > 0.05). There was more resorption by volume in the force group when compared to the no-force group (P < 0.05). Conclusion Mechanical vibration did not have a beneficial effect on reducing root resorption; however, force application caused significant root resorption.
Friction is a fundamental aspect of orthodontic movement. Researchers and clinicians must be acquainted with its biomechanical and physical principles, as well as the potential alterations that may occur with the use of diverse materials. This literature review presents an approach of the physical principles at work in frictional mechanics, an analysis of the friction, at macro and microscopic level, of different orthodontic materials; describes the influence of friction on tooth movement and presents an update on friction research and its relationship to various materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.