2018
DOI: 10.1016/j.talanta.2018.01.053
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive hexavalent chromium determination at bismuth film electrode prepared with mediator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 42 publications
0
6
0
Order By: Relevance
“…The fabricated sensor showed the ability of the detection of Cr(VI) with a low background noise due to the decoration of the carbon frame by bismuth electrodeposited. In another work, electroplating of bismuth onto the glassy carbon electrode with a reversibly deposited zinc mediator in the presence of DTPA has been carried out successfully by Katarzyna Tyszczuk-Rotko and coworkers [ 43 ]. The use of zinc as a mediator enhanced considerably the intensity of the analytical signal of Cr(VI), 1 µA vs. 3.3 µA for bismuth film electrode prepared without and with zinc mediator respectively leading to the detection of an extremely low concentration of 3.01 × 10 −6 µg·L −1 .…”
Section: Electrochemical Sensors For Hexavalent Chromium Determinamentioning
confidence: 99%
See 2 more Smart Citations
“…The fabricated sensor showed the ability of the detection of Cr(VI) with a low background noise due to the decoration of the carbon frame by bismuth electrodeposited. In another work, electroplating of bismuth onto the glassy carbon electrode with a reversibly deposited zinc mediator in the presence of DTPA has been carried out successfully by Katarzyna Tyszczuk-Rotko and coworkers [ 43 ]. The use of zinc as a mediator enhanced considerably the intensity of the analytical signal of Cr(VI), 1 µA vs. 3.3 µA for bismuth film electrode prepared without and with zinc mediator respectively leading to the detection of an extremely low concentration of 3.01 × 10 −6 µg·L −1 .…”
Section: Electrochemical Sensors For Hexavalent Chromium Determinamentioning
confidence: 99%
“…The constructed sensor could also be used for total chromium quantification and that after the oxidation of Cr(III) by the use of hydrogen peroxide (H 2 O 2 ) whereas Cr(III) content was calculated by subtracting the Cr(VI) concentration from total Cr [ 78 ]. Another research group has developed a specific sensor for chromium determination at ppt level [ 43 ]. The in situ electroplated GCE by bismuth film in the presence of a zinc mediator was combined with differential pulse cathodic adsorptive stripping voltammetry for Cr(VI) sensing.…”
Section: Sensors and Biosensors-based Chromium Speciationmentioning
confidence: 99%
See 1 more Smart Citation
“…Chromium is one of the most widespread elements in the earth's crust. The predominant forms of Cr in the environment are trivalent chromium and hexavalent chromium (Cr(VI)) . Although trivalent chromium is a trace element essential for the maintenance of glucose tolerance in human organism, Cr(VI) is highly toxic and carcinogenic .…”
Section: Introductionmentioning
confidence: 99%
“…15 These desirable proprieties are used in a unique and relatively novel type of the renewable mercury film silver based electrode (Hg(Ag)FE) constructed by Baś and Kowalski, [16][17][18] which have been widely used in numerous electroanalytical applications. [19][20][21][22][23][24][25][26][27][28][29] Further research in the field of mercury-free film electrodes have led to invention of the bismuth, [30][31][32] lead, 33,34 antimony [35][36][37] and tin [38][39][40] film electrodes, using metals much less toxic than mercury. Despite many advantages of these solutions, the metallic film plating procedure is much more complicated and time-consuming than in case of the mercury and amalgam film electrodes, which are unique examples of the electrodes which can be deposited mechanically.…”
mentioning
confidence: 99%