2011
DOI: 10.7785/tcrt.2012.500206
|View full text |Cite
|
Sign up to set email alerts
|

Ultra-Fast Digital Tomosynthesis Reconstruction Using General-Purpose GPU Programming for Image-Guided Radiation Therapy

Abstract: The purpose of this work is to demonstrate an ultra-fast reconstruction technique for digital tomosynthesis (DTS) imaging based on the algorithm proposed by Feldkamp, Davis, and Kress (FDK) using standard general-purpose graphics processing unit (GPGPU) programming interface. To this end, the FDK-based DTS algorithm was programmed "in-house" with C language with utilization of 1) GPU and 2) central processing unit (CPU) cards. The GPU card consisted of 480 processing cores (2 3 240 dual chip) with 1,242 MHz pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 65 publications
0
16
0
Order By: Relevance
“…Finally, although the use of nonclinical research software for DTS was time consuming, it is reasonable to expect that computation times for CB-DTS reconstruction of projections might be significantly reduced, for example, by using the graphic card engine 32 and enhanced computational algorithms. 33 In a clinical environment, automated DTS registration could potentially be used to verify intrafraction target position with a warning signal when CB-DTS derived target position deviated from the Reference-DTS by more than a certain threshold. In addition, DTS might be used in addition to a standard CBCT, to provide fast positional verification prior to radiation delivery, including for example when unexpected changes in the respiratory signal occur.…”
Section: Discussionmentioning
confidence: 99%
“…Finally, although the use of nonclinical research software for DTS was time consuming, it is reasonable to expect that computation times for CB-DTS reconstruction of projections might be significantly reduced, for example, by using the graphic card engine 32 and enhanced computational algorithms. 33 In a clinical environment, automated DTS registration could potentially be used to verify intrafraction target position with a warning signal when CB-DTS derived target position deviated from the Reference-DTS by more than a certain threshold. In addition, DTS might be used in addition to a standard CBCT, to provide fast positional verification prior to radiation delivery, including for example when unexpected changes in the respiratory signal occur.…”
Section: Discussionmentioning
confidence: 99%
“…To combine the reconstruction with an automated registration and interpretation algorithm, however, further speed improvements might be required. This could either be achieved by reconstructing a limited field of view or alternatively the utilization of more computational power using e.g., a GPU [22].…”
Section: Cranial Transitionmentioning
confidence: 99%
“…For another image modality called digital tomosynthesis , whose reconstruction formula is identical to that for CBCT, GPU has also been applied. The most computationally intensive backprojection part was first ported to GPU (Yan et al , 2007; Yan et al , 2008) and then the filtering part was later realized via GPU-based FFT using the CUDA library CUFFT (Park et al , 2011). …”
Section: Imaging-related Problemsmentioning
confidence: 99%