2001
DOI: 10.2116/analsci.17.175
|View full text |Cite
|
Sign up to set email alerts
|

Tungsten Coil Devices in Atomic Spectrometry: Absorption, Fluorescence, and Emission

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0
1

Year Published

2002
2002
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 50 publications
(22 citation statements)
references
References 25 publications
(35 reference statements)
1
20
0
1
Order By: Relevance
“…Better detection limits can be reached since blank values are usually lower than 0.01 A s [147,148]. Moreover, permanent modifiers prolong atomizer lifetime, providing enhanced thermal stability and repeatability [28,43,46,79,97,107,[147][148][149][150]. Currently, no single chemical compound can be identified as having a broad application for the determination of other elements.…”
Section: Modifier Use and Chemical Vapor Generationmentioning
confidence: 99%
“…Better detection limits can be reached since blank values are usually lower than 0.01 A s [147,148]. Moreover, permanent modifiers prolong atomizer lifetime, providing enhanced thermal stability and repeatability [28,43,46,79,97,107,[147][148][149][150]. Currently, no single chemical compound can be identified as having a broad application for the determination of other elements.…”
Section: Modifier Use and Chemical Vapor Generationmentioning
confidence: 99%
“…2,10 The tungsten coil was extracted from a commercial standard slide projector bulb (Osram, BRJ, 15 V, 150 W, Munich, Germany), and was positioned in the center of the radiation beam. A gaseous mixture composed of 90% Ar + 10% H2 at a flow-rate of 1.0 L min -1 was used as the purge gas.…”
Section: Instrumental Set-upmentioning
confidence: 99%
“…Despite the lack of a commercial instrument, the use of the tungsten coil atomizer in AAS is gradually increasing. [1][2][3][4] The main drawback of AAS associated with each of these atomizers is the single-element nature of the measurement. Ongoing efforts to overcome this drawback have focused on the graphite-furnace atomizer.…”
Section: Introductionmentioning
confidence: 99%
“…Em 2001, Hou et al 49 realizaram estudos do emprego de modificador químico permanente para determinações de Cd, onde 200 µg de irídio foram depositados sob a superfície do filamento. O uso deste modificador propiciou um aumento da vida útil do filamento, chegando a atingir 1000 ciclos de aquecimento, quando na maior parte dos trabalhos desenvolvidos normalmente são reportados de 150 a 300 ciclos de aquecimentos.…”
Section: Monitoramento De Marcadores Alimentícios Em Animaisunclassified