Transient behaviour of salient-pole synchronous machines with internal stator winding faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
28
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 51 publications
(28 citation statements)
references
References 16 publications
0
28
0
Order By: Relevance
“…Three Gorges Power Station will be one of the largest power stations in the world. Research results illustrated that the employed schemes including the differential protection scheme, the split-phase transverse differential protection scheme and the unit transverse differential protection scheme would have a blind zone [1][2]. For example, for the short circuit happened between 81.25% (from neutral) and 89.58% in the first branch in phase A (termed as A 1 ), the transient currents are very small, all schemes are unable to detect.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Three Gorges Power Station will be one of the largest power stations in the world. Research results illustrated that the employed schemes including the differential protection scheme, the split-phase transverse differential protection scheme and the unit transverse differential protection scheme would have a blind zone [1][2]. For example, for the short circuit happened between 81.25% (from neutral) and 89.58% in the first branch in phase A (termed as A 1 ), the transient currents are very small, all schemes are unable to detect.…”
Section: Introductionmentioning
confidence: 99%
“…Because the large generator has large size and great cost, the various faults such as the internal fault may cause serious results to the machine. Thus, the requirements need to be fulfilled are stringent for the generator protective systems [1][2].…”
Section: Introductionmentioning
confidence: 99%
“…The calculation of the winding inductances has been described in detail in [15] and [16]. It is worth mentioning that for a salient-pole generator, the self-and mutual-inductance between segments of the stator winding, and the mutual-inductance between the stator and rotor windings are dependent on the angular position of the rotor; while the self-and mutual-inductances of the rotor windings are independent of the angular position of the rotor.…”
Section: Establishment Of State Equationsmentioning
confidence: 99%
“…The method has been verified by experiments, and shown to be capable of analyzing the steady-state and transient behavior of internal faults in the stator windings of synchronous generators [16], [17] since it accounts for the actual disposition of the windings and accurately calculates the harmonics in the air-gap field. However, since the distributed capacitances of the windings to ground are neglected, while the grounding method for the neutral is not considered, ground faults could not be simulated and analyzed.…”
mentioning
confidence: 99%
“…Alternatively in [9][10][11], the synchronous machine is assumed to be formed from several electric loops and the inductances are calculated on a coil-by-coil basis. The capacitive effect in modeling of the faulted machine is also considered in [12] and mutual inductance of faulted machine was precisely calculated by use of winding function approach in [13].…”
Section: Introductionmentioning
confidence: 99%