2014
DOI: 10.1016/j.sab.2014.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Trace and ultratrace determination of heavy metal ions by energy-dispersive X-ray fluorescence spectrometry using graphene as solid sorbent in dispersive micro solid-phase extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(19 citation statements)
references
References 30 publications
0
19
0
Order By: Relevance
“…Lachance-Traill equation with α factor was used for correcting matrix effects in pellets and beads. For paper disks, the calibration curves were obtained by linear regression of the intensity ration of WLα/TaLα against the percentage ration of W(%)/ Ta(%), and any correction was not needed because the matrix effect in thin layer sample was almost negligible [21].The resulting equations and their respective correlation coefficients are shown in Fig. 1.…”
Section: Calibrationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Lachance-Traill equation with α factor was used for correcting matrix effects in pellets and beads. For paper disks, the calibration curves were obtained by linear regression of the intensity ration of WLα/TaLα against the percentage ration of W(%)/ Ta(%), and any correction was not needed because the matrix effect in thin layer sample was almost negligible [21].The resulting equations and their respective correlation coefficients are shown in Fig. 1.…”
Section: Calibrationsmentioning
confidence: 99%
“…For borate fusion and filter paper disk, the SD and RSD of both methods were lower than 0.1% and 1.0%, respectively, suggesting that their precision could meet the requirement of tungsten assay. The main reason for their good reproducibility was that, compared with pressed powder pellet, borate fusion and filter paper disk could eliminate particle size effects and reduce or eliminate matrix effects [21,23].…”
Section: Comparison Of the Precision Of Different Sample Preparation mentioning
confidence: 99%
“…Therefore, the XRF technology has difficulties in obtaining 3D information for low-density materials with low-Z elements. If possible at all, for even a very light matrix with trace amounts of heavy elements, the very simple determination of trace heavy elements cannot give information about the matrix features (Kocot and Sitko 2014). However, for different low-Z elements or matrix, they have different scattering cross-sections.…”
Section: Confocal X-ray Scatteringmentioning
confidence: 99%
“…However, EDXRF has low sensitivity and it may be difficult to use liquid and volatile samples, such as sugar cane spirit. Thus, it is common to include a step for metal extraction and preconcentration prior the determinations using the EDXRF [16][17][18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%