2009
DOI: 10.1016/j.arth.2008.04.010
|View full text |Cite
|
Sign up to set email alerts
|

Total Hip Arthroplasty with a Collarless, Tapered, Fiber Metal Proximally Coated Femoral Stem

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
13
1
1

Year Published

2009
2009
2013
2013

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 20 publications
3
13
1
1
Order By: Relevance
“…Mean HHS was 98 (range 86-100), and all patients available for radiographic follow-up had stable, bony ingrown stems [24]. Klein and colleagues reported similar results in their study of 129 hips implanted with an FMT at a minimum five year followup, with a mean HHS of 92% and 100% survival of the FMT component [16]. Butler et al reviewed the results of 91 patients at a minimum ten year follow-up who had a THA with a similar component, the Anatomic Hip, which is also a collarless, titanium stem with a proximal, circumferential coating of fibre metal mesh.…”
Section: Discussionsupporting
confidence: 64%
See 3 more Smart Citations
“…Mean HHS was 98 (range 86-100), and all patients available for radiographic follow-up had stable, bony ingrown stems [24]. Klein and colleagues reported similar results in their study of 129 hips implanted with an FMT at a minimum five year followup, with a mean HHS of 92% and 100% survival of the FMT component [16]. Butler et al reviewed the results of 91 patients at a minimum ten year follow-up who had a THA with a similar component, the Anatomic Hip, which is also a collarless, titanium stem with a proximal, circumferential coating of fibre metal mesh.…”
Section: Discussionsupporting
confidence: 64%
“…There was one case of early periprosthetic fracture with subsidence that required revision. This 1% fracture rate is less than Akhavan and Goldberg's reported rate of 6%, and Klein et al described two intraoperative fractures during seating of the FMT stem out of 129 implanted stems [16,24].…”
Section: Discussioncontrasting
confidence: 39%
See 2 more Smart Citations
“…3.2) are available for THA components (femoral stem and acetabular cup implants) and TKA components with encouraging clinical outcomes. Recently, Klein et al [102] reported a 100 % bone osseous integration rate following THA with a collarless, tapered, fiber metal proximally coated femoral stem (Fiber metal taper TM , Zimmer, Warsaw, IN) at an average 6.7 years post-operatively. Similarly, Lachiewicz et al [103] reported an implant survival rate of 100 % at an average 10.5 years following THA with a second-generation fiber-metal proximally coated femoral stem.…”
Section: Fiber Metal Meshmentioning
confidence: 98%