volume 45, issue 11, P1224-1231 2005
DOI: 10.1088/0029-5515/45/11/002
View full text
|
|
Share

Abstract: In the moderate magnetic field of TCV (1.5T), the recently installed X3 system (3 gyrotrons @118GHz, 0.45MWeach, 2s) broadens the operational space with the possibility of heating plasmas at high density, well above the cutoff density of the X2 system. To compensate the significantly weaker absorption coefficient compared to the absorption of X2, the top-launch injection allows to maximize the ray path along the resonance layer thus maximizing the optical depth. To maintain the maximum absorption in plasma dis…